GD&T: Composite Profile With "Individually"

I made a mistake in using half of the .02 profile in the minimum wall calculation to the datum. The full profile should be used, not the .01 like I said in the video. Also, an all around symbol should be on the leader. I discuss composite profile applied to a pattern, with an individual form and size requirement. I show how the minimum gaps are calculated depending on what you are looking for. This is based on a question from the ASME GDTP Senior Certification exam.