Tektronix 465 repair
A thankfully easy Saturday morning repair to the power supply on a Tek 465. Fault was no display, not even when beam finder pressed otherwise the 'scope powered up OK. Capacitor was C1419 a 47uF Tantalum electrolytic which was shorted. Replacement was with a 220uF/50v aluminium electrolytic (Tants have very low ESR). The CH2 Variable switch coupling is fatigued and broken I found after recording this. That means the vertical board has to come out. Yikes! You win some ....and then get slapped around the face. Apologies for the dim lighting but I wanted the screen to be visible and the Sun is very bright today.

▶︎
Tektronix 465 & 465B Oscilloscope Repair

▶︎
Tektronix 465 Non B troubleshooting and repair LV and HV supplies

▶︎
Tektronix 465 No Display

▶︎
Tektronix 465 Repair (Horz sweep Issues)

▶︎
Tek 465 Repair

▶︎
#172 Tektronix 465 Repair Part 2

▶︎
Tektronix 465 Oscilloscope - pcb fault

▶︎
Tektronix 465B Restoration Part 1 Power Supply and Tube

▶︎
HP 6060B Electronic Load

▶︎
No.135 - Tektronix 465 Oscilloscope Repair

▶︎
Tektronix 465B Board Removal Video (A Deeper Look)

▶︎
Tektronix 465B: Repair

▶︎
Tektronix 2245A Oscilloscope Repair Part 1

▶︎
Tektronix 475A Power Supply and Scope Repair (With Soldering)

▶︎
Mixing Desk Repair - Soundcraft EFX12

▶︎
#217 Tektronix TAS 465 Simple Service Tips

▶︎
Tektronx 475A , Textronix , Textronic scope repair , Oscilloscpe repair

▶︎
Tektronix 465 oscilloscope gamble

▶︎
Jim Williams Tek 465B Fix v3

▶︎