Tektronx 475A , Textronix , Textronic scope repair , Oscilloscpe repair
While using my Tektronix 475A Oscilloscope it Quit working ? Taking it apart I found there was no -8 volts . Having had a bad filter capacitor before I assumed it was a bad filter capacitor and replaced the filter capacitor for the -8 volt power supply section this was WRONG . After doing this and wasting a couple of hours I got out the Service manual on this scope and see that the power supplies voltages are to be checked in a certain order and the +5 volt supply provides power to the -8 volt power supply section and the + 5 volt section was not working either . So this was a case of " If all else fails read the instruction manual " So the manual testing procedure showed the actual problem to be in the +5 volt power section . After several hours the problem was isolated not to a bad filter capacitor but a very unusual intermittent in the +5 volt full wave bridge rectifier . It was quite a process locating this and repairing it without a major disassembly of the oscilloscope . Due to the unusual nature of this condition and the difficulty finding it then repairing it I decided to make this video and perhaps help someone repairing their oscilloscope or other equipment with a full wave bridge rectifier in it . I was about to end the video and the camera quit the display on the camera showed that the memory chip was full so this video lacks only my typical ending 73 and good DX . Bob

Tektronix 465B Restoration Part 1 Power Supply and Tube

EEVblog #803 - HP1740A Analog Oscilloscope

Tektronix 475A Power Supply and Scope Repair (With Soldering)

Tektronix 475A Trigger Transistor Testing 151 0367 00 (Do NOT replace unless proven faulty!)

Tektronix 475A and DM44 Repair Power Supply and Logic

Unbelievable Workers | Working with Talented Engineers #46 #fail #adamrose #smartworkers

DR #27 - Tektronix 2213A Oscilloscope CRT Replacement & Tune-Up

#172 Tektronix 465 Repair Part 2

Tektronix Type 442 Oscilloscope Diagnosis and Repair

Junk Box Oscilloscope, Can It Be Fixed?

Tektronix 465B Restoration Part 3 Trigger and Timebase

Tektronix 465B Board Removal Video (A Deeper Look)

#170 Tektronix 465 Review troubleshoot Pt 1

AE#4 Repair Of A Tektronix TDS 460 Four Channel Oscilloscope

Tektronix 2445a Analogue scope. Is it worth repairing?

Tek 465 Repair

Unbelievable Smart Worker & Hilarious Fails | Construction Compilation #8 #adamrose #smartworkers

Tektronix 468 Repair - Vol. 1 - Storage +5 Supply

Oscilloscope Restoration

