CÓMO DETECTAR DEFECTO A TIERRA | PARTE #1 | AVERÍA ELECTRICIDAD

http://www.domoelectra.com/detectar-d... How to detect a ground fault or fault, part 1. Electrical fault, tripped RCD. Subscribe, no power http://goo.gl/yGSZ3O :) Hello, DOMOEQUIPO! Excited, motivated! This week we're dealing with an unusual fault. In our first contact with the client, he tells us that his 16 A circuit breaker tripped unexpectedly. He also feels a current inside his house when touching certain metal objects. What could be causing this fault? In this DomoAdventure, we're once again detectives for a day. WILL YOU JOIN ME? After this initial assessment, everything points to an equipotential grounding problem or improper grounding installation. The variables are many and diverse, so it's best to identify the possible problem. We found the 16 A circuit breaker down, and when we raised it, the RCD tripped, which suggests a possible ground fault. The next step is to examine the output wires of said mechanism to see where they flow. Curiously, when leaving only the 16 A circuit breaker and the RCD connected, the latter doesn't trip. Logically, we tested all the connected circuit breaker swaps to see when the circuit breaker trips or not. We concluded that the 10 A lighting circuit breaker is also influenced by the fault (remember the light bulb that was supplying power?). We disconnected the light bulb and reset the 10 A circuit breaker, but the RCD continues to trip. Given the circumstances, we also noticed that the connection cables had reversed their polarity, so we reversed their connection order (neutral on the right, neutral on the left), but the same problem described so far persists. The next step is to measure the grounds with our clamp meter. After all the checks, when measuring phase and ground, it gives us 390.5 V instead of 230 V. And when measuring neutral to ground, it's approximately 200 V, when it should be 0 V. This suggests that the problem is coming from outside the house, not inside. So, we continue investigating. When we located the ground wire outside the home, it was bare, rusty, and moldy. We disconnected it and rechecked the electrical panel, giving us the same results. What does this mean? No ground wire is installed. Since prevention is better than insurance, we ultimately used a multifunction meter that confirms the initial measurements. We performed a differential trip test, and curiously, since it's over 280 V, it chooses not to act for safety reasons. From what we've seen, it's all clear. We have a serious grounding problem, and a new ground rod will need to be installed. But we'll see about that next week. More technical stories at http://goo.gl/piJGdt Would you like it? RT it? Share it? These things, believe it or not, help us optimize our videos :) I've left links to all the products featured in the video available in your online store: 1. Multifunction tester: http://www.domoelectra.com/tiendaonli... 2. KRANG Clamp Meter: http://www.domoelectra.com/tiendaonli... 3. Ground rod: http://www.domoelectra.com/tiendaonli... 4. Schneider Residual Current Device: http://www.domoelectra.com/tiendaonli... More info on the website: http://www.domoelectra.com Online Store: http://domoelectra.com/tiendaonline Your blog: http://www.domoelectra.com/blog DONATIONS: https://goo.gl/MbCePZ Free Download DomoGame Chapters 1 and 2: http://domoelectra.com/tiendaonline/8... Free Download DomoGame Chapter 3: http://www.domoelectra.com/tiendaonli... Domo Electra Android App: http://goo.gl/9tTbtR We follow you on social media: Twitter - http://goo.gl/G6D1Ef Facebook - http://goo.gl/n8reWp Google Plus - http://goo.gl/N7UdyH Instagram -   / domoelectra  

HOW TO DETECT A GROUND FAULT | PART 2 | ELECTRICAL FAULT
▶︎

HOW TO DETECT A GROUND FAULT | PART 2 | ELECTRICAL FAULT

Siempre cuando LLUEVE SALTA DIFERENCIAL y han venido TÉCNICOS del SEGURO y no RESUELVEN AVERÍA
▶︎

Siempre cuando LLUEVE SALTA DIFERENCIAL y han venido TÉCNICOS del SEGURO y no RESUELVEN AVERÍA

Esquema TT y TN explicado SIN HUMO
▶︎

Esquema TT y TN explicado SIN HUMO

🤔HOW TO FIND A SHORT CIRCUIT💥...a NEVER-BEFORE-SEEN method!!
▶︎

🤔HOW TO FIND A SHORT CIRCUIT💥...a NEVER-BEFORE-SEEN method!!

¡Una EXPERIENCIA NUNCA VISTA! INSTALO con NIÑO de 10 AÑOS un SOBRETENSIONES BIFÁSICO!
▶︎

¡Una EXPERIENCIA NUNCA VISTA! INSTALO con NIÑO de 10 AÑOS un SOBRETENSIONES BIFÁSICO!

New REBT: this is what a basic electrification panel will look like in 2026 ⚡ (MANDATORY)
▶︎

New REBT: this is what a basic electrification panel will look like in 2026 ⚡ (MANDATORY)

DESPAIR! THE DIFFERENTIAL BLOWS OUT! 5 technicians FAILED TO FIX THE ELECTRICAL FAILURE
▶︎

DESPAIR! THE DIFFERENTIAL BLOWS OUT! 5 technicians FAILED TO FIX THE ELECTRICAL FAILURE

Aprenda a usar cualquier multímetro digital con este curso para principiantes!
▶︎

Aprenda a usar cualquier multímetro digital con este curso para principiantes!

LA FUGA A TIERRA O DERIVACION A TIERRA EXPLICADA Y COMO MEDIRLA
▶︎

LA FUGA A TIERRA O DERIVACION A TIERRA EXPLICADA Y COMO MEDIRLA

DIFERENCIA entre tierra y neutro: No es lo mismo aunque están UNIDOS
▶︎

DIFERENCIA entre tierra y neutro: No es lo mismo aunque están UNIDOS

UNCONTROLLED Electrical Panel with DUENDE (Regulatory Electrical Measurements)
▶︎

UNCONTROLLED Electrical Panel with DUENDE (Regulatory Electrical Measurements)

AC vs. A Type Differential: The Truth Revealed
▶︎

AC vs. A Type Differential: The Truth Revealed

Why does the differential jump every 2x3 for no apparent reason? Real-life case and solution
▶︎

Why does the differential jump every 2x3 for no apparent reason? Real-life case and solution

MIND-BLOWING Electrical Fault Makes No Sense! 🤯 Can We Fix It?
▶︎

MIND-BLOWING Electrical Fault Makes No Sense! 🤯 Can We Fix It?

WHAT'S HAPPENING IN THIS ELECTRICAL PANEL? THE THREE-PHASE DIFFERENTIAL IS TRIPPING
▶︎

WHAT'S HAPPENING IN THIS ELECTRICAL PANEL? THE THREE-PHASE DIFFERENTIAL IS TRIPPING

Como detectar fuga de corriente electrica ⚡⚡⚡
▶︎

Como detectar fuga de corriente electrica ⚡⚡⚡

Goodbye to ELECTRIC CARS?
▶︎

Goodbye to ELECTRIC CARS?

Cómo revisar la Conexión a Tierra de una casa - Paso a Paso...
▶︎

Cómo revisar la Conexión a Tierra de una casa - Paso a Paso...

Revealing The SPECIAL TECHNIQUE Of A Pakistani Man To EXTRACT GOLD From Used Motherboard Waste
▶︎

Revealing The SPECIAL TECHNIQUE Of A Pakistani Man To EXTRACT GOLD From Used Motherboard Waste

95% of people are doing this terminal block WRONG‼️
▶︎

95% of people are doing this terminal block WRONG‼️