Б5-44, часть 3 - ремонт ИОН, улучшение термостабильности, настройка коррекции, замена реле ЦАП
Support the channel: 4100 1111 8764 9602 (yoomoney)! The saga of replacing the power supply toggle switch continues. In a perfectly functional B5-44 DC power supply, also often referred to as a linear laboratory power supply, the toggle switch handle accidentally broke. During the replacement process, a simple repair gradually evolved not only into in-depth preventative maintenance, but also into a bit of collective farming, as well as adjusting the characteristics for maximum precision. In the third part, we'll repair a shorted ION voltage regulator, replace ION components to improve its thermal stability, compare the thermal stability of the K140UD1B and K140UD7 operational amplifiers, analyze the effect of printed circuit board traces on the thermal stability of zero voltage and current, replace all relays, and compare the idle power consumption before and after relay replacement. The B5-44 DC power supply is a linear compensating DC voltage regulator, combined in parallel with a linear compensating DC voltage regulator. The output voltage is adjustable from 0 to 29.9 V in 0.1 volt steps. The output current is adjustable from 0 to 999 mA in 1 milliamp steps. Due to the absence of any switching circuitry, the B5-44 power supply provides extremely low output ripple and noise – in voltage regulation mode, ripple does not exceed 3 mV at full load. Equipment and materials used in the video: B5-44 power supply - patient; XJW01 RLC digital meter (off-camera); HP 34401A voltmeter; Robiton PM-3 wattmeter; MAS838 multimeter with "Type K" thermocouple; Oscilloscope C1-77; Alarm clock Granat PT109; Banana plugs, alligator clips, and probes; Microsoft Excel .2010 spreadsheets.

B5-44, part 4 - two modifications based on recommendations, final testing upon completion of all ...

Б5-44, часть 1 - замена тумблера питания и прочий попутный ремонт, а также колхозинг светодиодов

Building and using a 741 based Noise Generator - #242

Милливольтметр В3-48 - ремонт, настройка и калибровка, часть 2

Scott Ritter’s Shocking Report From Inside Russia

Где горячий конец вторички 3

B5-44, Part 2 - New Capacitors, Decade Resistance Analysis, Error Check

Device Searches 2026: What the FSB Looks for at the Border and How to Hide Your Data

В7-22А и РВ7-22А - настройка и калибровка всех режимов работы, постоянный ток и низкая частота

Jeffrey Sachs: The Greater Israel Project is Collapsing

Милливольтметр В3-48 - ремонт, настройка и калибровка, часть 1

Б5-45 - Самовозбуждение в канале напряжения. Проверка погрешности установки выходного напряжения.

Почему все ненавидят Горбачёва? Неожиданная причина катастрофы СССР | ФАЙБ

The 1.25V Trick That Gives You Any Voltage You Want

Jack Ma. He wasn't killed, he wasn't imprisoned... They did something worse

Ф4320 - измеритель RLC, часть 1 - общий осмотр, вскрытие пациента, осмотр внутренних органов

Ф4320 - измеритель RLC, часть 4 - чистка, проверка переключателей, замена конденсаторов, опробование

F4320 - RLC meter, part 2 - board repair #1: generator, power amplifier, phase shifter

