⚡ N + PE = FI-Schalter löst aus! 🤨 Aber warum? 🤔 ultimative Erklärung 💡 | Das musst du wissen 👷♂️
Why does the residual current device (RCD) trip when the neutral conductor (N) and the protective conductor (PE) are connected? This video explains in detail what such a short circuit entails. _____________________________________________________________________ DUSPOL two-pole voltage tester on Amazon* | Advertisement: https://amzn.to/2Y432vo KNIPEX electrical installation pliers on Amazon* | Advertisement: https://amzn.to/3F2HVtJ _____________________________________________________________________ Jump marks: 0:00 Introduction 0:32 Switching the neutral conductor?! 1:03 TN-C-S system 1:25 Protective devices - TN-C-S system 2:02 Disconnecting - TN-C-S system 2:47 Plug-in unit - Current divider rule 3:38 Danger from the neutral conductor? - TN-C-S system 4:56 N+PE causes current flow?! - TN-C-S system 5:50 N+PE causes RCD to trip?! - TN-C-S system 6:15 Danger from N+PE? - TN-C-S system _____________________________________________________________________ You can find my second channel on YouTube here: / elektrikerwerkzeugmaterial _____________________________________________________________________ You can find more information on my website: http://www.Der-Elektriker.org/ _____________________________________________________________________ Advertising: Support me and my channel by purchasing from Amazon*: http://amzn.to/2fS92QX _____________________________________________________________________ I would appreciate a comment, a positive rating, or a subscription. _____________________________________________________________________ Disclaimer: The respective provider or operator of the linked pages is always responsible for the content of the linked pages. All information in this video is provided without guarantee! I assume no liability for the accuracy of the content. Electricity is life-threatening! Working on electrical systems requires specialist knowledge and special training. Electrical work may therefore only be carried out by qualified personnel! This video is not an instructional video and is not intended to encourage imitation! Everyone is responsible for their own actions and mistakes! I assume no liability for any resulting property damage or personal injury! Further information: http://der-elektriker.org/disclaimer/ _____________________________________________________________________ By purchasing through an "affiliate link," I receive a commission on the sale. There are NO additional costs for the buyer! These links are therefore also marked with the note "advertising." The YouTube channel "Der Elektriker" is a participant in the Amazon EU Affiliate Program, which is designed to provide a medium for websites to earn advertising fees by placing advertisements and linking to Amazon.de. _____________________________________________________________________ Imprint: http://der-elektriker.org/impressum/

Alle Netzsysteme / Netzformen ausführlich erklärt 💡 TT- / IT- / TN-S / TN-C-S-System im Vergleich 🔌

N + PE = FI-Schalter löst aus! Aber warum? Das solltest du wissen 🤷🏻♂️

Brandschutzschalter (AFDD) - Schutz vor elektrischen Bränden 🔥 | Funktion und alle wichtigen Infos

Der PERFEKTE Unterverteiler! Unterverteilung mit RCD, Überspannungsschutz verdrahten. DIN18015

🔌 RCD einfach erklärt – Was macht ein Fehlerstromschutzschalter? ⚡

FI-Schalter FLIEGT! - Große Fehlersuche bei meinem Cousin (Teil 1) ElektroM

STECKDOSEN prüfen😱Spannung messen 👍Benning Duspol digital ⚡Freunde des Stroms⚡

Retrofitting residual current devices (RCDs) in old buildings⚡TN-C network | Converting old elect...

Why Circuit Breakers DON'T Protect People (electric shocks)

RCD Typ "AC", "A" und "B": Der gefährliche Unterschied

Ground Neutral and Hot wires explained - electrical engineering grounding ground fault

With this trick, anyone can install a residual current device (double crimp)‼️

MIND-BLOWING Electrical Fault Makes No Sense! 🤯 Can We Fix It?

The $5 battery that never dies — Edison hid this secret 100 years ago

Verboten ! Teil1: RCD/FI Schalter bei Nullung 😲 Elektrik im Altbau erneuern. FI Schalter nachrüsten.

Should I dismantle my solar panels now or what? This accusation is insane!

RCD - FI Schalter im Test / Billig RCD sind Lebensgefährlich ! Fehlerstromschutzschalter

Wieso N und PE auf der PEN Klemme?! ElektroM

So GEFÄHRLICH ist der Neutralleiter wirklich! ElektroM

