We Replaced a 21-Year-Old AC Before Lunch | 4-Ton ACiQ Heat Pump Install
Can a complete 4-ton central HVAC system really be replaced before lunch? We get it done so we can go to the bar for lunch! In this full, uncut installation, Mikey Pipes and the Pipe Doctor team remove a 21-year-old Carrier central air-conditioning system and replace it with a high-performance ACiQ Extreme+ communicating inverter heat pump system in Woodmere, New York. We started at approximately 7:30 AM—and had the new system heating and cooling before noon. The old Carrier equipment still looked surprisingly clean from the outside, but its indoor evaporator coil had developed a refrigerant leak. At 21 years old, investing in a major repair no longer made financial sense. The homeowners chose to upgrade to a modern inverter-driven heat pump capable of providing efficient cooling and heating throughout the year. This video shows the entire process with nothing hidden: ✅ Pumping down the old Carrier system ✅ Removing the overgrown outdoor condenser ✅ Installing a heavy-duty wall-mounted heat pump bracket ✅ Keeping the outdoor unit above the Long Island snow line ✅ Reusing and professionally reforming the existing line set ✅ Creating and torqueing new flare connections ✅ Installing the Mikey Pipes SPD-01 surge and voltage protection panel ✅ Wiring the ACiQ S1/S2 communicating system ✅ Nitrogen pressure testing ✅ Pulling a deep vacuum measured in microns ✅ Charging the system with R-454B refrigerant ✅ Installing the ACiQ communicating thermostat ✅ Measuring the system’s actual amperage ✅ Testing its whisper-quiet operation At the end of the installation, this 48,000-BTU inverter heat pump was operating at approximately 13 amps while cooling the home. That is the advantage of modern inverter technology. Instead of repeatedly starting and stopping at full capacity, the system can automatically adjust its output based on the actual heating or cooling demand inside the home. This can provide more consistent temperatures, quieter operation, improved humidity control and greater energy efficiency. You’ll also see why evacuation is one of the most important parts of any HVAC installation. Air and moisture left inside a refrigeration system can contribute to acid formation, contaminated oil and premature compressor failure. Anyone can bolt equipment onto a house—the work you cannot see is what often determines how long that equipment will last. And then there’s the Fieldpiece core removal tool… After another frustrating leak during the vacuum and commissioning process, Mikey finally had enough. Watch until the end to see exactly what happened and why the tool received the full “Fisher-Price Fieldpiece” treatment. NEED HVAC SERVICE ON LONG ISLAND? Pipe Doctor Plumbing, Heating & Cooling provides professional HVAC, plumbing and heating services throughout Nassau County, Queens and portions of western Suffolk County. 📞 516-348-6300 🌐 pipedoc.net Located in Woodmere, New York. HVAC CONTRACTORS: BECOME AN ACIQ DEALER Get access to ACiQ inverter heat pumps, central HVAC systems, ductless equipment, dealer pricing, technical support and contractor resources. Dealer information and signup: https://aciq.com/mikeypipes When asked who referred you, select Mikey Pipes YouTube or tell your ACiQ account manager that Mikey Pipes sent you. ACiQ’s official dealer materials describe access to competitive pricing, a dedicated dealer portal, technical support and marketing resources. Dealer terms and available benefits may vary by account and dealer level. Subscribe, hit the notification bell and share this video with an HVAC technician, contractor or homeowner who wants to see what a professional inverter heat pump installation actually involves. Tell us in the comments: Would you trust the Fieldpiece core removal tool after seeing this? CHAPTERS 00:00 Complete 4-Ton HVAC Replacement Before Lunch 01:40 Why the 21-Year-Old Carrier Had to Go 04:00 Pumping Down the Old Refrigerant 08:05 Pump-Down HVAC Tech Tip 10:15 Removing the Ivy-Covered Carrier Condenser 13:30 Cleaning and Preparing the Installation Area 16:05 Why the Heat Pump Is Going on the Wall 19:20 Moving the 4-Ton ACiQ Outdoor Unit 22:30 Installing the Heavy-Duty Wall Bracket 27:10 Keeping the Heat Pump Above the Snow Line 30:15 Preparing the ACiQ Extreme+ Outdoor Unit 33:40 Bending, Cutting and Flaring the Line Set 38:05 Torqueing the Refrigerant Connections 41:10 Proving the Factory Clearance Requirements 44:20 Installing the Mikey Pipes SPD-01 48:05 Nitrogen Test and Deep-Vacuum Setup 50:00 Why a Deep Vacuum Is So Important 53:10 How to Become an ACiQ Dealer 54:35 ACiQ Communicating S1/S2 Wiring 56:15 Fieldpiece Core Tool Starts Leaking 58:00 Adding R-454B and Starting the System 59:15 Four-Ton Inverter Pulling Approximately 13 Amps 1:00:05 Whisper-Quiet ACiQ Performance 1:00:35 Mikey’s Final Fieldpiece Verdict HASHTAGS #ACiQ #HeatPumpInstallation #HVAC

HVAC: Can This Dead Fujitsu 3 Zone Mini Split Heat Pump Be Saved? Full Compressor & PCB Replacement

Dual Zone Heat Pump System Install pt.2 Electrical Connections And Supply.

EMERGENCY LEAKY CARRIER "CHICKEN CHILLER"

R-32 vs R-454B A2L Refrigerant! Which Is My Favorite And Why?!!

4 TON ACiQ EXTREME+ Heat Pump Install | ONLY 5 AMPS?! Full Uncut HVAC Replacement

Why Would Anyone Mount a Heat Pump Like THIS? | ACiQ Side Discharge Done Right

NO A/C in a Brand New Home? Here's What I Found

Harley Locked me out of My Own Motorcycle. The $100m Experiment

I Installed a DUCTED Mini Split in My Pole Barn (DIY Spiral Ductwork)

I Replaced My Gas Boiler with Air Conditioning… Was It Worth It? (2 Years Later)

ACiQ 4 Ton Extreme+ Heat Pump Install | Full Attic Air Handler & Line Set Job

Slant Fin Hydronic Baseboard Installation - Adding Comfort to Den Extension

Three Helicopter Crashes in Eleven Months. The Cause Was Built at the Factory!

Complete Mini-Split Heat Pump Installation: Fixing My Mistake

25-Year-Old AC System Replaced with Ultra-Efficient Mikey Pipes by ACiQ | Side Discharge Heat Pump

THEY SAID PLEASE HURRY THE AC'S ARE NOT WORKING

The AC Was Cooling... So Why Was the House Still Humid?

Splitklimaanlagen sind der DIY Endgegner!

This Family Couldn’t Afford A $65,000 Recovery… So I Did It Free

