S Plan wiring using Wago 221 and mBox L32 junction box.
We review the Wago mBox L32 junction box used for S-Plan heating wiring. The L32 wiring centre uses the popular Wago 221 connector. It's designed to improve upon the popular Honeywell 10-way junction box, which has been used extensively for central heating wiring. We put the Wago mBox to the test in a common configuration of S-plan wiring using a Nest heat link. Using Wago connectors speeds up wiring time, but what about the other features in this design. On an S-Plan wiring, we found that we quickly ran out of terminals. Using a Nest heat link to remove separate room thermostat and timeclock components did not solve this. The manufacturers wiring diagram omits most of the CPC (earth) connections but strangely does not on the Y plan wiring diagram. The second major problem is the lack of enough cable clamps. Two cable clamps were not enough to accommodate the seven cables in our mockup. It was a real challenge to get six cables under the grips. We are usually big fans of the Wago products, but we don't think this one delivers. The use of Wago 221's does reduce the wiring time, but we feel this box should have many more terminals and much more wiring room to cope with the ever-growing complexity of today's heating systems. ** More Wago content from eFIXX ** Wago 221 review • Wago 221 vs traditional connector strip: i... Wago 224 - Lighting connectors • Wago 224 connector block demonstration - g... *** Sign up to the eFIXX Newsletter https://www.efixx.co.uk/signup Subscribe to the channel https://www.youtube.com/efixx?sub_con... *** Honeywell junction box used for comparison. https://www.screwfix.com/p/honeywell-... *** Wago mBox L32 Part no 60362958 https://www.amazon.co.uk/Junction-Con... Features Gary Hayers @GSHElectrical #efixx #wago #L32

CONNEXBOX/WAGOBOX - How to accommodate the new Wago 2273 and 221 series

BIGGEST DIY Mistakes Joining Cables

You should definitely avoid using this clamp incorrectly! Proofwood

S plan wiring the basics. Diagram made easy to understand and follow

The Junction Box for Heating Systems - Wago 207-4301

Wago 221 vs traditional connector strip: including demonstration and testing point

How to connect cables with Wago 221 junction box & Wago 221 connectors. Join two cables the easy way

Wago 221 Klemme // richtig benutzen // anschließen // Lösen // verbinden// DEUTSCH

WAGO 222 connectors review and demo. How to use with WAGOBOX Junction Box.

Diese Fehler werden leider oft gemacht mit Wago Klemmen! Proofwood

How To Wire And Test Heating Systems. 2 Port, 3 Port, S Plan, Y Plan Etc. Part 2

Building a IP66 junction box using WAGO TOPJOB DIN rail terminals - S-Plan wiring

The Ultimate Guide to the Wago 221 Inline Connector

Y plan wiring - made simple

Wago Pro Junction Box: The Ultimate Time-Saver for Electricians! ⚡🔧

Fitting an RCBO in a Consumer Unit

95% of people are doing this terminal block WRONG‼️

Domestic Heating System Wiring using a Wago Wiring Centre - B Electrical London

S-PLAN wiring nightmare - NEW WAGO Junction Box to the rescue - Netatmo thermostat upgrade.

