How to Change Exhaust Filters in R5 RA Vacuum Pumps

If the counterpressure is too high or if smoke is coming out of the exhaust of your vacuum pump, it is time for a filter change. This will restore your vacuum pump to optimum performance. Our maintenance video shows you how to change the exhaust filters in R5 vacuum pumps. The Busch Genuine Maintenance Kit contains all parts for an efficient filter change. To ensure a long life and an efficient operation of your vacuum pump, we recommend our globally available Busch Service. We can do the whole maintenance and overhaul for you. Contact us via https://www.buschvacuum.com/contact/ 00:30 Tools 00:47 Busch service checks 01:12 Measure filter pressure 01:27 Shut off vacuum pump 01:32 Remove exhaust filters 02:22 Replace and lubricate o-rings 03:27 Install new exhaust filters 04:46 Replace gasket on exhaust cover