Me da CORRIENTE los electrodomésticos y tras la instalación de Placas Solares pago MÁS en la Factura
After installing a Combi Pro Max, José began noticing power surges in his appliances and an increase in his electricity bill. In this video, we analyze his solar installation, measure voltage, leakage, and power, and discover a serious error: a phase connected to ground, causing unnecessary consumption and electrical hazards. We applied the Amate brothers' measurement protocol step by step to detect the fault and ensure the installation is safe, efficient, and compliant with regulations. 📍 Timestamps 00:00 – José explains the problem after the solar installation 00:52 – Start of the Amate brothers' measurement protocol 01:27 – Voltage measurement and two-phase grid detection 02:55 – Loop impedance with the KPS 6010 04:45 – Leakage measurement: 420 mA with no apparent consumption 06:14 – Fault explanation: phase connected to ground 06:55 – Power measurement 08:10 – Calculation of the cost of grounded energy (€14.4/month) 10:10 – Review of protections and installation errors 11:07 – Fault correction and leak check 12:16 – Voltage tests after correcting the ground connection 19:04 – Review of the two-phase inverter operation 20:05 – Stable solar production and standardized bill 20:28 – Recommendations Endings and morals 🧰 Tools used in the video 🔗 KPS Multicheck 6010 Multifunction Tester https://www.domoelectra.com/tiendaonl... 🔗 KPS DCM300 LEAK TRMS Leakage Clamp https://www.domoelectra.com/tiendaonl... 🔗 KPS DCM5000PW Harmonics Power Clamp https://www.domoelectra.com/tiendaonl... 🔗 KPS DCM350 TRMS 600 A Mini Clamp AC https://www.domoelectra.com/tiendaonl... 🔗 Permanent self-resetting surge protector Toscano Combi Pro Max https://www.domoelectra.com/tiendaonl... 🔗 Vigivolt V2T-15B transient surge protector https://www.domoelectra.com/tiendaonl... 🔗 Differential type A super-immunized Toscano VDA 30 mA https://www.domoelectra.com/tiendaonl... 🔗 Knipex insulated tools https://www.domoelectra.com/tiendaonl... 💬 Conclusion Poor wiring can cause ground faults of more than 400 mA, electrical risks, and higher electricity bills. Never connect a phase to ground. Make sure your installation complies with the REBT (Regulatory Protection Regulation), with appropriate residual current devices and overvoltage protection. 📞 Do you have questions or would you like us to check your installation? 👉 Technical WhatsApp: 958 156 153 🎬 If you want my brother and I to install it for you, leave the word "LEAK" in the comments, and I'll send you my WhatsApp and the product link. We have a network of installers throughout most of Spain. And since we learn together every day... follow me, like, and save this video so you don't lose touch. Otherwise... we might never see each other again. GENEREEEN! ⚡

Siempre cuando LLUEVE SALTA DIFERENCIAL y han venido TÉCNICOS del SEGURO y no RESUELVEN AVERÍA

Flames erupted in this solar installation: the mistake you MUST NEVER make

Segunda carta que recibo diciendo que mi contador está en mal estado¿Algo que decir @e-distribucion?

9 LIES You're Being Told About Solar!

IT WAS SUPPOSED TO BE IMPOSSIBLE: I disconnected ALL the NEUTRALS in a 40-year-old apartment and ...

Power Optimisers - What are they? And do you really need them?

SE ME VA LA LUZ ME SALTA EL DIFERENCIAL 3 VECES AL DIA.( FUGAS, ARMÓNICOS, TENSIÓN POR TIERRA, ETC)

Errors in self-consumption installation with two inverters

Andalusians against solar farms | ARTE.tv Documentaries

10 years with the taps giving off current… and nobody knew why (95V)

How to Install a 7 kWh Battery Step by Step So You're Never Stranded | ATMOCE

Analizo AVERÍA midiendo ARMÓNICOS en CUADRO ELÉCTRICO con RUIDOS (Salta DIFERENCIAL M.E.R.)

Protecciones ELÉCTRICAS en CORRIENTE CONTINUA DC que DEBE llevar tu INSTALACIÓN de PLACAS SOLARES

Unbelievable Use of a Refrigerator Compressor – Revealed to Millions

DANGER! 50A Neutral on three-phase 😱 See how we reduced it to ZERO by balancing loads

DESPAIR! THE DIFFERENTIAL BLOWS OUT! 5 technicians FAILED TO FIX THE ELECTRICAL FAILURE

How to keep power at home after a blackout without batteries | Steps before island mode (actual i...

£20,000+ Battery System RUINED By This 1 Simple Mistake 😳

I have a voltage of 48 volts between neutral and ground. Is the ground faulty or is it the neutral?