0'genral pcb repairing step by step .
ac pcb repairing course 9213717087 , 9667663078 [email protected] dc inverter ac is video me inverter ac ka pcb hai. ye pcb o general ac ka hai is pcb me pehle humne check kiya to smps kaam thik nahi ker rahi thi to humne dekha smps ki output me voltage kum ban rahi hai voltage kam jyada ho rahi hai humne fir smps ko kese check kiya . o general invrter ac ki pcb ki voltage ko hume check kese kese kiya fir tab ja ker hume pata laga ki iski ek coil kharab hai fir humne coil ko change kiya to voltage thik ho gaye or saath me hum bhi khush ho gaye , lakin ye khushi jyada der nahi rahi . humne smps to repair ker di. ab bari thi pcb ko chala ke dekhne ki fir humne indoor our outdoor ke pcb ko connect kiya line se line ko neutral se neutral ko signal se signal ko . yehi sab khatam nahi hua . fir hume o general inverter ac ko on kiya on kerne ke baab kafi der wait kiya 4-5 minutes wait kerne ke baad bhi output yani ki uvw output nahi aai fir hume pcb ko test kerna shuru kiya check kerte kerte humne dekh ye to bootstrap capacitor ki voltage hi drop ho rahi hai fir humne paya ek resister kharab hai tab ja ker bhi isme problem thik hui . [email protected] subscribe this channel so friends thank you Face book : https://www.facebook.com/profile.php?... Instagram : https://www.instagram.com/raj232430/?... Thanks

O General Ac Green Light Blinking Solution Step by step Pcb repair | ac cooling problem Solution

11-06-26 Sukhmani Sahib Full Path | ਸੁਖਮਨੀ ਸਾਹਿਬ ਪਾਠ | Sukhmani Sahib Da Path | Fast Sukhmani

Ich hab den Tesla durchpoliert... 💩

Frequency Of God 963 Hz ✨ Attract Miracles, Divine Blessings & Deep Inner Peace In Your Life

O General AC Outdoor Fan Not working Problem solved|O General inverter AC Outdoor Pcb Repair

How to check IPM in AC PCB by giving supply to it. IPM Testing Live in AC PCB. Find out whether I...

MISSION 73 (2026) Full Action Movie | Akshay Kumar | John Abraham | New Bollywood Superhit Movies

Hitachi Ac pcb outdoor indoor communication working details | Inverter ac pcb repairing institute

daikin inverter 3=4 amp per compressor shut down

AC PCB Power Relay Full Tutorial | AC PCB Repairing Course | Power Relay Working & Testing in AC PCB

HOLY ROSARY TODAY THURSDAY, JUNE 11, 2026 ST. JUDE THADDEUS & LUMINOUS MYSTERIES | DAILY HOLY ROSARY

pcb repairing inverter ac inverter fridge

Hitachi inverter ac communication error , outdoor led 9 time blinking

10-06-26 Sukhmani Sahib Ji\ਸੁੱਖਾਂ ਦੀ ਮਨੀ ਸੁਖਮਨੀ ਸਾਹਿਬ ਪਾਠ\ Japp Sahib #punjabi #wmk #motivation

O General PCB AC link DC link Test - Is Microcontroller Turning On?

blue star pcb repairing blue inverter AC

Faulty Switching Power Supply: Complete Repair in Practice

Inside a 3000W Water-Cooled Power Supply (with GaN & SiC)

O'general AC compressor on nahi ho raha hai PCB Repairing

