【漏電ブレーカ】遮断•不良回路•復旧

This article introduces how even non-electricians can investigate and repair faulty circuits. ① Identify the name of the faulty circuit (the off mini-breaker) and identify the affected area.  (If the mini-breakers do not have names, try each one individually to find the affected area.) ② Unplug the affected area.  (Refrigerator, washing machine, kitchen exhaust fan, water heater, microwave, air conditioner, etc.) ③ If you cannot find the problem with ②, turn off the affected light. ④ If ② and ③ do not work, or if some products require disassembly to remove the outlet or are directly connected to a wall outlet, please contact an electrician. *In addition to insufficient capacity and faulty electrical appliances, other possible causes of power outages include faulty building wiring (rodents, leaks, short circuits caused by nails or screws during DIY work, or deteriorated wiring). *Electric leakage can also be affected by weather. Identifying the cause can be difficult, as a breaker may trip when it's raining or humid, but not when it's sunny. When I can't identify the cause, I install a high-sensitivity branch earth leakage breaker (15mA high-speed type) on the suspect circuit rather than the installed earth leakage breaker and see what happens. If you found this helpful, please subscribe and like my channel. #Electricalwork #Restoration #Amateur #DIY

[Power breaker not tripping] 5 possible causes!
▶︎

[Power breaker not tripping] 5 possible causes!

[For the general public] Explaining the reasons and solutions when your home's circuit breaker tr...
▶︎

[For the general public] Explaining the reasons and solutions when your home's circuit breaker tr...

【これで解決!!】漏電の原因調査手順を徹底的に解説します
▶︎

【これで解決!!】漏電の原因調査手順を徹底的に解説します

[Earth Leakage Circuit Breaker] Differences in sensitivity current!
▶︎

[Earth Leakage Circuit Breaker] Differences in sensitivity current!

Why Circuit Breakers DON'T Protect People (electric shocks)
▶︎

Why Circuit Breakers DON'T Protect People (electric shocks)

【漏電ブレーカ遮断】復旧手順Part1
▶︎

【漏電ブレーカ遮断】復旧手順Part1

防災最前線 強い地震の二次災害「通電火災」対策 感電ブレーカー
▶︎

防災最前線 強い地震の二次災害「通電火災」対策 感電ブレーカー

[What is the cause?] How to check for electrical leakage for electricians! [Knowledge Edition]
▶︎

[What is the cause?] How to check for electrical leakage for electricians! [Knowledge Edition]

No More Gas Cylinders! How I Made Free Gas All Year just a Fridge Compressor and Water?
▶︎

No More Gas Cylinders! How I Made Free Gas All Year just a Fridge Compressor and Water?

eevBLAB 91 - Why Are Fluke Meters So EXPENSIVE?
▶︎

eevBLAB 91 - Why Are Fluke Meters So EXPENSIVE?

ブレーカーが良く落ちてしまう原因と、復旧方法、漏電チェック
▶︎

ブレーカーが良く落ちてしまう原因と、復旧方法、漏電チェック

【これで解決】安全ブレーカーがすぐ落ちる場合の対処法
▶︎

【これで解決】安全ブレーカーがすぐ落ちる場合の対処法

【停電ブレーカが落ちている】考えられる5つの原因
▶︎

【停電ブレーカが落ちている】考えられる5つの原因

【漏電⁈】電気がつかない・ブレーカーが落ちる 対処方法《徹底解説》
▶︎

【漏電⁈】電気がつかない・ブレーカーが落ちる 対処方法《徹底解説》

Explanation of the General Store's Breaker ① How the Earth Leakage Breaker Works
▶︎

Explanation of the General Store's Breaker ① How the Earth Leakage Breaker Works

Macgregor: Neue Welt – Israel stirbt, NATO tot & USA von Iran besiegt
▶︎

Macgregor: Neue Welt – Israel stirbt, NATO tot & USA von Iran besiegt

漏電ブレーカーが落ちた時の対処法
▶︎

漏電ブレーカーが落ちた時の対処法

[What to do when there is a power leak] How you reset the circuit breaker can be life-threatening
▶︎

[What to do when there is a power leak] How you reset the circuit breaker can be life-threatening

120V 240V Electricity explained - Split phase 3 wire electrician
▶︎

120V 240V Electricity explained - Split phase 3 wire electrician