05/05/2021 Bell Test (Siemens FireFinder w/ EVAC) (SYSTEM DEFUNCT)
Conducted another bell test today. This is in a 14-story apartment building (13 regular floors plus a penthouse). The system is a Siemens FireFinder with EVAC. The common areas (major rooms, hallways, and stairwells) have speaker/strobes and the apartments have sounder/smokes and heat detectors in them. There are some apartments that also have remote strobes for the hearing impaired. There are no speakers in the apartments. With the exception of studio apartments, when one apartment smoke detector is triggered, it sends a supervisory signal to the FACP. Should a second detector in that apartment activate, it initiates an alarm condition. If a heat detector activates, it automatically triggers an alarm condition. When an alarm condition is received, the floor where the alarm originated, the floor above, the floor below, and both stairwells play the slow whoop alarm tone and the apartment sounder/smokes on the floors in alarm activate as well. All other floors play the Alert message over the speakers and the sounder/smokes remain silent. All strobe lights activate regardless of what tone/message is playing. You'll notice I encounter a couple of confused residents while making my rounds, as they had activated strobe lights in their apartments and no advance notice was given about any testing taking place. I checked floors 1-5, my colleague checked the penthouse and floors 6-12, and a building maintenance employee checked the ground floor. This is the most complex EVAC system I've come across yet, as all the others have the entire building sounding the alarm tone/message at once, not in a phased manner. Neat! UPDATE: as of 2022, this system has been replaced with a Honeywell 6820EVS.

Fire Alarms Sounding at the Providence Place Mall | Siemens FireFinder Voice Evacuation

06/24/2026 Bell Test (Fire-Lite MS-5UD)

Siemens Voice Evac System test at University of West Florida commons in Pensacola Florida

New System Test 1
![“This is a Test of the Fire Alarm System” (Fire Alarm A/V Test) [08-01-2025]](https://i.ytimg.com/vi/g-6eHVTAd-Q/hqdefault.jpg?sqp=-oaymwEjCNACELwBSFryq4qpAxUIARUAAAAAGAElAADIQj0AgKJDeAE=&rs=AOn4CLDgUvsOCw9xuf1GMMSTeg8Judybxg)
“This is a Test of the Fire Alarm System” (Fire Alarm A/V Test) [08-01-2025]

06/04/2021 Bell Test 2 (Simplex 4100ES)

Fire alarm goes off at Virginia Beach Convention Center!

BRAND NEW System test 1

Fire Alarms of the Gadsden Hotel | (Hotel Impossible)

Fire Alarm at the Westin Pittsburgh

Former Home Fire Alarm and Mass Notification System Test 10

06/23/2026 Bell Test (Fire-Lite MS-9600UDLS)

Fire Protection/Life Safety System Tour of the Birthplace of the Internet (UCLA Boelter Hall)

System test 11 

Fire Alarm at Retirement Home | Siemens MXL

World Trade Center | Fire Alarm Sounds, WTC 1,2,4,5,6,7

Simplex Network Test 2. 4100ES. Rare Voice Evac Messages and Code-4 CO.

from the field: female notifier voice evac

Exploring MIT underground tunnels, #3

