How to Size and Build Switching Transformers | Testing a Planar Transformer
In this video I go through the main calculations to size transformers for SMPSs and I build a planar transformer with PCB windings and test it on a half bridge 250kHz converter. I didn't talk about the advantages of planar transformers to avoid making a boring lecture video. In general though, they are: Lower stray inductance, compact shape and size, and ease during assembly, particularly for interleaving windings. Check out my video on building a half bridge converter: • Building and Testing a Half Bridge SMPS Huge thanks to PCBWay for making this video possible! Check them out at https://pcbway.com/g/nPngMb to order PCBs for your projects. PCBWay gerber file viewer: https://www.pcbway.com/project/Online... Music: Kevin MacLeod - Lobby Time Kevin MacLeod - Groove Grove Kevin MacLeod - George Street Shuffle Kevin MacLeod - Space Jazz 0:00 Intro 0:22 1) Losses in the copper windings 1:49 2) Limiting magnetizing current 2:12 3) Avoiding core saturation 2:45 4) Losses from magnetic hysteresis & eddy currents 3:11 Designing the PCB windings 3:36 Ordering the PCBs (sponsor) 4:32 Assembling the transformer 5:05 Test result: one sided PCB, single secondary 5:17 Test result: two sided PCB, single secondary 5:45 Test result: two sided PCB, double secondary 6:57 Outro

Building and Testing a Half Bridge SMPS

Why higher frequency transformers are smaller

Practical Transformer Winding Tutorial 2019

EEVblog 1752 - Texas Instruments SCREWED UP the NE5532!

No more Transformers, STOP Spending Money on Transformers.

The Grid | Planar Magnetics: The Evolution of the Transformer

Building a Tiny 10W Buck Converter and Testing It

Ferrite transformer calculations for SMPS

ASMR Addictive Fast Tapping Collection For Deep Sleep & Anxiety Relief (No Talking) — 2.5 Hours

Why the US Navy's "Dead" Railgun Just Fired Again
![[430] How To Calculate Ferrite Core Maximum Power Handling to Design High Frequency Transformer](https://i.ytimg.com/vi/Fk2OeYY_poo/hqdefault.jpg?sqp=-oaymwEjCNACELwBSFryq4qpAxUIARUAAAAAGAElAADIQj0AgKJDeAE=&rs=AOn4CLAVq7gHYGbf5AmQh40z9HQGELR5Jg)
[430] How To Calculate Ferrite Core Maximum Power Handling to Design High Frequency Transformer

Magnetic Design and Validation of a 500 kHz, 18 kW "Intra-Leaved" Litz Wire Transformer

What's NEW at✨SAM'S CLUB✨ + June 2026 INSTANT SAVING!!

Using an Ultra Low Noise SMPS (Switching power supply). How it Achieve Low Noise Performance

The 1.25V Trick That Gives You Any Voltage You Want

Everything You Need to Know About Soft Switching (Switching Loss, ZVS, ZCS)

Making a Synchronous Buck-Boost Converter Based on the ATtiny10

High Performance Motor Control From the Ground Up || Field Oriented Control (FOC)

در بعضی از دستگاه ها ترانس صدای وز. وز میده. دلیلش خیلی ساده هست!!

