Vaillant Got It Wrong - A Day In The Life Of A Gas Engineer 119

Vaillant got it wrong on this occasion. They sent out an engineer to investigate an issue with the boiler, and he put it down to poor circulation and said the system was blocked and needed a powerflush. Customer got me in to flush the system, only to find at the end there was still an issue with the boiler which could have been rectified in the first instance had it been correctly diagnosed. #plumbing #heating #boiler https://unilite.co.uk/?ref=uncle Use code UNCLE for 25% off Powered Now - Job Management Software https://www.powerednow.com/cputility-2 towel radiator vaillant ufh underfloor heating blockage magnetite scale lockshield radiator valves electric boiler electrical wiring

Multimeter Fault Finding, Y Plan Repairs, Diagnosing Combi's | Day In The Life Of A Gas Engineer #19
▶︎

Multimeter Fault Finding, Y Plan Repairs, Diagnosing Combi's | Day In The Life Of A Gas Engineer #19

The Fault That Defied Logic! (And My Experience)
▶︎

The Fault That Defied Logic! (And My Experience)

Heat Pump Retrofit In a Victorian House. Is It Even Possible?
▶︎

Heat Pump Retrofit In a Victorian House. Is It Even Possible?

Vaillant ecotec plus loosing pressure
▶︎

Vaillant ecotec plus loosing pressure

How a Boiler Fires Up: Step-by-Step Sequence Explained
▶︎

How a Boiler Fires Up: Step-by-Step Sequence Explained

The Classic "My Boiler Needs A Service" - A Day In The Life Of A Gas Engineer 93
▶︎

The Classic "My Boiler Needs A Service" - A Day In The Life Of A Gas Engineer 93

I Bet You All Get This One Wrong!
▶︎

I Bet You All Get This One Wrong!

Gas engineer or cowboy,  looking at common combi  boiler faults found when servicing or repairing.
▶︎

Gas engineer or cowboy, looking at common combi boiler faults found when servicing or repairing.

Practical demonstration on how to comply with igem/up/1b edition 4 tightness testing and purging.
▶︎

Practical demonstration on how to comply with igem/up/1b edition 4 tightness testing and purging.

Did I Undersize The Gas Supply For This Vaillant 940? - A Day In The Life Of A Gas Engineer 84
▶︎

Did I Undersize The Gas Supply For This Vaillant 940? - A Day In The Life Of A Gas Engineer 84

Ex Gas Safe Inspector Explains The New Tightness Test Rules w/ Terry Sawyer
▶︎

Ex Gas Safe Inspector Explains The New Tightness Test Rules w/ Terry Sawyer

The most ridiculous worker fails caught on camera
▶︎

The most ridiculous worker fails caught on camera

Is There Anything Worse For A Heating Engineer??
▶︎

Is There Anything Worse For A Heating Engineer??

How Easy is it to move a boiler? We had to walk away from this one!
▶︎

How Easy is it to move a boiler? We had to walk away from this one!

Day In The Life Of A Gas Engineer #10 | Gas Leaks, Boiler Repairs, Wiring & Going Back To School
▶︎

Day In The Life Of A Gas Engineer #10 | Gas Leaks, Boiler Repairs, Wiring & Going Back To School

DO WE OR DON'T WE, a look at what is required when carrying out a service on a gas boiler.
▶︎

DO WE OR DON'T WE, a look at what is required when carrying out a service on a gas boiler.

£20,000+ Battery System RUINED By This 1 Simple Mistake 😳
▶︎

£20,000+ Battery System RUINED By This 1 Simple Mistake 😳

Ventilation tutorial for trainee gas engineers PART 1
▶︎

Ventilation tutorial for trainee gas engineers PART 1

How To Replace a Vaillant Water Pressure Sensor, F75 in the Display, Step by Step Instructions
▶︎

How To Replace a Vaillant Water Pressure Sensor, F75 in the Display, Step by Step Instructions

Gas Training - How A Combi Boiler Works With Roy From Viva Training Academy
▶︎

Gas Training - How A Combi Boiler Works With Roy From Viva Training Academy