EC&M Tech Talk Video — Medium-Voltage Conductors and Cable
In this episode of “EC&M Tech Talk,” Randy Barnett, a journeyman electrician, inspector, author, trainer, and electrical safety expert, reviews requirements for medium-voltage conductors and cable. Randy covers Art. 315 of the National Electrical Code, which addresses requirements for medium-voltage conductors and cable such as listing requirements, construction, installation, and ampacity requirements. Medium-voltage conductors are those rated from 2,001V up to and including 35,000V. For demonstration purposes, Randy uses a length of Type MV 90 cable with 2 AWG copper conductor. It is a shielded solid-dielectric conductor rated for 5kV maximum if the application calls for 133% insulation and 8kV if the application calls for 100% insulation. Each of the ratings as well as insulation layers are discussed. Randy also provides a brief overview of Art. 495 regarding equipment that is more than 1,000VAC and 1,500VDC, nominal. He identifies each of the Parts of the Article. Maintenance of medium-voltage conductors and cable is referenced to the NFPA 70B, Standard for Electrical Equipment Maintenance. Safety (always an important consideration) is especially important with working with DC medium voltages. These cables tend to hold a significant charge. Workers must follow the safety requirements for installing personal protective grounds outlined in NFPA 70E.

EC&M Tech Talk — The Why, What, and How of High Potential (HiPot) Testing

How to Calculate the cable size and protective device rating

Electricians Know the Work… But Can They Teach It?

Medium Voltage Cable Construction and Design

Hazards, Best Practices, and How to Change Cutouts Safely

PFISTERER Connex | 33kV MV Medium Voltage Size 3 Bushing Connector Plugs

Understanding Medium Voltage Cable Aging: Preventing Power Failures
![Medium Voltage Drives [Pumps & Systems Podcast, Episode 89]](https://i.ytimg.com/vi/-MNBxVVibxE/hqdefault.jpg?sqp=-oaymwEjCNACELwBSFryq4qpAxUIARUAAAAAGAElAADIQj0AgKJDeAE=&rs=AOn4CLBuovLaFHFKl_POkQwH9ExQVyaA4A)
Medium Voltage Drives [Pumps & Systems Podcast, Episode 89]

Wiring With MC - WHAT YOU CAN AND CAN'T DO WITH MC CABLE as an electrician

Medium Voltage Drive Basics

Webinar Medium Voltage Cable Failures Root Causes and Online Detection

35kV Underground XLPE High Voltage Cable

⚡️High Voltage Power Lines ⚡️ - How Close is TOO CLOSE?

Secrets of MEDIUM VOLTAGE CABLE Production

🚗 BYD : The biggest SCAM of the car industry ?

EC&M Asks Video — Medium-Voltage Circuit Breaker Maintenance

Medium-voltage switchgear fundamentals | Eaton PSEC

3M QTII Cold Shrink Cable Terminations MV HV Medium High Voltage

15KV opening for hand taped splice