Finding Target Superheat
Bert teaches the Kalos techs some strategies for finding target superheat on systems with fixed-orifice metering devices (not TXVs). Whenever we take readings, we should start by knowing what we want our readings to look like; we should know what to expect of a system that is working properly so that we can recognize abnormalities in our readings. Superheat is an especially critical reading because it can let us know a system's risk of flooding the compressor, if the evaporator coil is being fed efficiently (as opposed to overfed or underfed), and the evaporator load, and it can help us diagnose problems with TXVs (on TXV systems). We can measure superheat on the suction line or discharge line, but those superheat values are very different and can tell us different things about the system. Suction line superheat readings that are too high can indicate that we are starving the evaporator, and low superheat readings can indicate that the system is feeding too much refrigerant into the evaporator coil (or that the coil is otherwise not absorbing heat sufficiently). When you have a metering device problem, like a wide-open TXV, the saturation point is a lot higher than it should be because the pressure stays higher and keeps the evaporator coil warmer. To find our target superheat, we need to take the outdoor dry-bulb temperature (sensible heat) and the return wet-bulb temperature (sensible heat + latent heat). You will need a psychrometer, a target superheat calculator (such as on hvacrschool.com or the HVAC School app), and a manufacturer target superheat chart; measureQuick can help you take these measurements. Once you know your target superheat, you can set the charge accordingly. A common rule of thumb is to achieve a 10-degree target superheat for fixed-orifice systems, but the target is variable because the superheat isn't constantly monitored and manipulated by the metering device (unlike a TXV system). On a fixed-orifice system, the target superheat will decrease as the outdoor dry-bulb temperature increases. Buy your virtual tickets or learn more about the HVACR Training Symposium at https://hvacrschool.com/symposium. Read all the tech tips, take the quizzes, and find our handy calculators at https://www.hvacrschool.com/.

Setting a Refrigerant Charge by Subcool

Class - What Superheat Signifies

Understanding Dry Bulb, Wet Bulb, and Dew Point: HVAC Properties of Air Explained

Refrigeration Basics with Elliot and Bert Part 1

Understanding Airflow: David Bowie, a Used Car Lot, and a 40¢ Tool with Alex Meaney

Saturation, Superheat, Subcooling

Critical System Diagnosis for Residential HVAC

Explaining Superheat and Subcooling to Your Apprentice!

HVAC 056 Target Superheat for a fixed metering device

Subcooling = Stacking Liquid Refrigerant (What Subcool really Signifies)

Static Pressure: What It Is, Why It Matters, and How to Read It

Mastering Superheat: The Trick to Charging an HVAC Unit

A2L Refrigerants - What The Contractor Needs To Know

Accumulator Facts & Tips

Liquid Line Restriction on AC Unit Explained! Found Bad TXV!

Total Superheat Method used to Check the Refrigerant Charge of AC's with a Fixed Orifice

Super Heat : Total System Superheat & Evaporator Superheat | Testo 550 Functions Part 1

HVAC 106 Scenario Restriction and non-condensable

What is Superheat? - HVAC Training