#5 N4 Tridium Niagara - Commission an iSMA MAC36NL controller - N4 Software - BMS and HVAC systems.
Machine learning - Commission a MAC36NL controller, add BACnet MSTP and MODBUS drivers. Clean dist a MAC36NL controller back to factory settings. The iSMA-B-MAC36NL is a Niagara controller with 36 onboard IO and a license of 100 points and one RS485 port. If more points are needed then you can upgrade in 50 points increment. See https://bmsparts.co.uk for more information. The MAC (Master Application Controller) with built-in different types of I/O and operating in the Niagara Framework environment. Using the specific local I/O set 16x UI, 8x AO, 4xDI, and 8x DO allows to use the device in different applications. The controller provides control, data logging, alarming, scheduling, integration, and visualization. To allow IP connectivity there are 2x Fast Ethernet ports that can operate as two independent ports. Built-in 1x RS485 can be used to expand the number of I/O by connecting MINI or MIX series I/O modules or to integrate with other subsystems. iSMA-B-MAC36NL provides a rich graphical interface displaying on a standard Web browser or on an external display connected to a built-in HDMI and USB port (touch-screen support). Main features 16x Universal Inputs (16UI) All Universal Inputs have 16-bit ADC which support the following types of inputs: Temperature input supports the following types of sensors: 10K3A1, 10K4A1, Carel 10K, 20K6A1, 2.2K3A1, 3K3A1, 30K6A1, SIE1, TAC1, SAT1, Pt1000, Ni1000 For sensors Pt1000 and Ni1000 use only 16-bit resolution! Voltage input 0-10 V DC: input resistance 100 kΩ accuracy ±0,1%, measurement resolution 3 mV @ 12-bit and 1 mV @ 16-bit Current input 0-20 mA (external resistor 200 Ω required) Resistive input 0-1000 kΩ: measurement resolution for 20 kΩ load: 20 Ω @ 12-bit and 1 Ω @ 16-bit Dry contact input 4x Digital Inputs (4DI) Dry contact inputs Fast pulse counter up to 100 Hz saved in SD Card 8x Analog Outputs (8AO) All Analog Outputs are equipped with 12-bit ADC provides 10 mV resolution and accuracy less than ±0,5%. They support the following output types: Voltage: 0-10 V DC max. load up to 20 mA PWM: 0,01 Hz, 0,1 Hz, 1 Hz, 10 Hz, 100 Hz 8x Digital Outputs (8DO) Relay output (NO): max. 3 A @ 30 V DC Platform Multicore Cortex-A Series ARM Processor 1GB DDR3 SDRAM Removable micro-SD card – 4 GB (2 GB system reserved / 2 GB user storage) Communication RS485 half-duplex, opto-isolated Baud rate from 2400 to 115200 2x Fast Ethernet (independent) 2x USB (1x OTG, 1x Host) HDMI type A (standard) Micro SD card slot Modbus RTU/ASCII/IP, BACnet MSTP/IP, oBIX, SNMP, LON/IP, KNX/IP Power supply 24 V AC/DC Housing Dimensions: 160x110x62 mm. Construction: UL approved, self-extinguishing plastic (PC/ABS) DIN rail mounting DIN (DIN EN 50022 norm) Cooling: internal air circulation Environment Operating temperature: -10°C to 50°C Storage temperature: -40°C to 85°C Relative humidity: 5% to 95%, no condensation Ingress Protection Rating: IP40 – for indoor installation

#6 N4 Tridium Niagara - Machine learning - Two Pump simple logic with auto-rotation

Setting up the LocalIOs on iSMA-B-MAC36NL

HOW TO: Commission iSMA-B-MAC36 Controller

Niagara 4: Creating a Simple Graphic (PX)

Meta’s AI Clusterf*ck Is Humiliating Zuckerberg

Stuttgart 21 - verplant, verbaut, verschoben. Von falschen Kabeln und doppelten Signalen | SWR Doku

HOW TO: Generate Simple Reports in Niagara 4 using BQL & ReportPX

Modbus integration to Tridium JACE/Supervisor

Industrial Control Panels In Depth Look Part 1: Power Distribution
![The Best Acid Jazz, Funky & Soul | Nu Chill & Acid Jazz Classic [Vol. 9]](https://i.ytimg.com/vi/LYtesxX546M/hq720.jpg?sqp=-oaymwEbCNAFEJQDSFryq4qpAw0IARUAAIhCGAG4AvcY&rs=AOn4CLDs7cZQ-CcbCdsQcYycqWIWLYw6MA&usqp=CCc)
The Best Acid Jazz, Funky & Soul | Nu Chill & Acid Jazz Classic [Vol. 9]

iSMA Tool 3 - Work with Device Kits window

Instant Focus Mode – 40Hz Gamma Brainwave Music for Deep Focus & Productivity

Top people are leaving Google - some deliberately

iSMA Device Manager: Quick Start for Niagara 4 Module

Basics of HVAC Controls - Control Loops and Sequences

Niagara PRO TIPS: Schedule Relations Part 3 – BACnet Schedule Exports

Inside Factory Process of Recycling Copper Stator Scrap Into New Royal Largest Copper Vessel

#197 N4 Tridium Niagara - Popup Alarm Console

