Das Glaser- Verfahren (Tauwasser Berechnung)

The Glaser method can be used to check if, where, and how much condensation forms in a structure. NOTE: Due to constantly changing standards and boundary conditions, there is no guarantee of its accuracy! The calculations are generally still correct (as of 2016), but some values ​​in the standard climate conditions have since changed. You should use the current values, which should be found in the latest editions of the relevant reference books. 3:54 Here, I unfortunately mixed up inside and outside. The insulation should, of course, be on the outside, but this doesn't change the subsequent calculations. Only the final result would be different. The PDF with all the important formulas: http://goo.gl/EnuIP2 If you'd like to support me, you can do so using Nano (XRB): xrb_3rzt4d857ouf16foak917i6u6dpby43qsdqgdedizsfu3fmwy97x3zfincnr