Impianto elettrico 3kW me lo faccio da solo
https://app.thesalers.com/r/gd6gXWFEP... As part of the renovation of a small apartment, I also worked on the 3kW electrical system. First, however, I checked the type of system. It's an old electrical system from the 1960s with the classic cables buried in the wall. After 1990, it was retrofitted with a circuit breaker. After checking with a phase tester, I determined that the system was Phase/Phase, not Phase/Neutral. FOR EVERYONE LISTENING, I DON'T HAVE A NEUTRAL, AND IT HAPPENS IN ROME! 😅 And to this end, I've attached a link to a YouTube video: • #72 Nell'impianto elettrico bifase posso u... , which illustrates the situation in some areas of Rome. This factor influenced the choice of cable colors. In fact, considering that black, brown, or gray cable is generally used for the Phase, while blue is used for the Neutral and the yellow-green ground wire, in my new Phase/Phase system, there will be no blue (neutral) cable. Therefore, I purchased black, gray, and brown cables in addition to the yellow-green cable. I took advantage of the lack of screed to run the corrugated pipes for the new underfloor system. Although the electrical, TV, and telephone lines will be separated with dedicated junction boxes, I did not choose the corrugated pipes. Since they were given to me, I used them based on quantity and diameters of 20 mm and 25 mm. The CEI 64-100/2 guide recommends these colors: Black: electricity distribution and home automation Blue: intercom system and audio/video distribution, Hi-Fi. Green: telephone system, TV, data transmission Brown: security alarm systems. This is advice, not obligation. The walls were marked for the corrugated pipes, junction boxes, sockets, switches, and emergency lights. In doing this, with the help of an electrician friend, the most optimal and shortest possible route was identified. On the advice of my electrician friend, before starting the work of breaking down the walls to create the routes, I quickly created a flying service circuit. After DISCONNECTING THE POWER, I disconnected the power cables from the old system and connected two temporary flying cables to the existing 10A and 16A switches, dedicated to a light and a socket, respectively. This isolated the old system and allowed me to work on the routes without having to worry about cutting any concealed cables that were now depleted of power. The thickness of the new cables will be: 4 mm² for the FM (Drive Power) backbones; 2.5 mm² for the light backbones and the FM (sockets); 1.5 mm² for the lighting line. To close the tracks, I used ready-made mortar - KC1 fine plaster - ZL25 leveling compound. The new electrical panel will have four circuits, compared to the two previous ones. There will be a main switch; lighting line; kitchen FM line; ordinary FM line, and an air conditioning switch. The 4 mm² cables enter the junction boxes located at the entrance and in the corridor inside 25 mm corrugated conduits, and from these, as many 20 mm corrugated conduits as there are switches and sockets. The junction boxes I built into the wall are large enough to accommodate all the corrugated conduits that will run from there; I used PT6 and PT8 (the cables that flow together inside take up a lot of space). Running the cables through the conduits would have required two people, but with a little patience, I managed to do it myself. After a few months, I can say that I haven't had any problems with my new system. N.B. DON'T DO IT, I CANNOT BE RESPONSIBLE FOR THE ACTIONS OF OTHERS. IT'S ALSO GOOD TO KNOW: https://www.rifarecasa.com/normative/... MY CONTACT DETAILS: Email: [email protected] Social Media: Facebook: / 1965gianni Instagram: https://www.instagram.com/p/CIG4cGRBU... Twitter: / indoleh Telegram: https://t.me/Indolehobbista Pinterest: https://www.pinterest.it/gianni2770/_... Catalog Tacklife: https://shareasale.com/r.cfm?b=178903... MY SHOP CATALOG https://www.amazon.it/shop/indolehobb... http://www.amazon.it/provaprime?tag=a... https://www.primevideo.com/?&tag=amaz... Laser Level https://amzn.to/2Dd52TV https://amzn.to/2KQ07iT Mini Circular Saw: https://amzn.to/30Uq2JW #electricalsystem #electricalpanel #junctionbox #circuitbreaker #circuitbreaker #lightcircuitbreaker #circuitbreaker

22.1 - Impianti elettrici, modifica quadro elettrico da 3 kW a 4,5 kW, evita scatti contatore

Never Buy a Water Pump Again! A 65-Year-Old Plumber Made His Own Water Pump Using PVC Pipes | Update

How to Install a Cable-Structure Solar Mounting System | Step 4 Main Cable & Anchor Installation

21.1 - Electrical systems, 3kW electrical switchboard. Selection of differential circuit breakers.

Quadro elettrico d'appartamento

The most ridiculous worker fails caught on camera

Scatola di derivazione: cosa ci troviamo al suo interno?

*19* MAIN JUNCTION BOX WIRING (6 kw "LEVEL 1" ELECTRIC PANEL)

INSTALLATION OF THE ELECTRICAL PANEL OF A HOUSE IN ACCORDANCE WITH THE WORKMANSHIP

95% of people are doing this terminal block WRONG‼️

Unbelievable Smart Worker & Hilarious Fails | Construction Compilation #1 #adamrose #smartworkers

#1 Electrical panel? What are the switches? #Advertising

HOW TO RUN WIRES FOR A BATHROOM ELECTRICAL SYSTEM

Elektro Verteiler für Wohnung

impianto elettrico, come collegare punti luce, lampadine #Pubblicità

Unbelievable Smart Worker & Hilarious Fails | Construction Compilation #5 #adamrose #smartworkers

Unbelievable Smart Workers Compilation 2026 🚧👷 Smart Engineers vs Construction Fails #38

*34* COMPLETE WIRING FOR ELECTRICAL JUNCTION BOX 1/2

99% of People Connect Wires WRONG , Do This Instead! ⚡

