Use of Steel Microfibers, Steel Macrofibers, PVA Fibers, and Hybrid Fibers in UHPC
Use of Steel Microfibers, Steel Macrofibers, PVA Fibers, and Hybrid Fibers in UHPC: Experience from Shear Tests and Bond Strength Tests of UHPC Beams Presented By: Manuel Bermudez, National Cheng Kung University The key for the outstanding post cracking behavior of UHPC is directly related to the presence of fibers which controls the crack width, crack growth and delays localization. Currently, the type of fiber that is mostly used is the steel microfibers because it is assumed that due to its size it would not disrupt the densely packed microstructure of the UHPC constituent materials. However, our laboratory experiments have shown that the inclusion of either steel macrofibers, PVA fibers, or hybrid fibers to the UHPC matrix generates additional benefits to the post cracking response of beams, particularly in shear. To achieve a UHPC matrix reinforced with fibers other than steel microfibers, it was necessary to conduct thorough preliminary mixes that would ensure that the fresh concrete will flow through steel reinforcing bars. The challenge of mixing hybrid fibers in a UHPC mix taught us the importance that the mixing time has in UHPC as well as understanding how and when to add the superplasticizer to obtain the required consistency of the material. When we evaluated the use of fibers as the only shear reinforcement, it was found that 2.25% of hybrid steel macrofibers were enough to ensure that the shear capacity was higher than the flexural capacity of a slender beam with 7.6% of longitudinal reinforcement. The addition of PVA fibers with steel macrofibers to the UHPC mix of the beams increased the toughness in the post cracking region, reduced the crack widths, and almost no concrete spalling was noticed. The superior performance of UHPC can also represent an obstacle in trying to investigate the design parameters such as the bond strength and splicing length of rebars in UHPC. It was found that in UHPC beam tests that had the splice length of only 40% of the required length per ACI 318 for normal concrete, flexural capacity developed by the reinforcing bars prevented bond failure

Real Time Plastic Viscosity Prediction Through Video Recognition

Steel fiber concrete reinforcement – how does it work?

NEXGen - Ultra High Performance Concrete

Durability of a Steel Fiber-Reinforced UHPC

The World's Most Important Machine

Creator of C++: Bell Labs, Negative Overhead Abstraction, Mistakes | Bjarne Stroustrup

FRP Rebar Breakthrough

Final Report: Fiber Optic Sensors—Ihsanul Azmi—114999408

Understanding Steels and Heat Treatment

ASMR Best Triggers For Sleep Collection (No Talking) 3 Hours of Tapping & Scratching

The Problem with Welding

Abstract Black and White wave pattern| Height Map Footage| 3 hours Topographic 4k Background

Billionaire's WARNING: I'm SELLING. The Crash Is Already Here!

Roman Catholic Mass for June 28th, 2026: Thirteenth Sunday in Ordinary Time

Self-Healing Ultra-High Performance Fiber Reinforced Concrete

Building Science Insights: To Vent or Not to Vent

ACI Level 1 - Concrete Field Testing Procedures Guide

Why Bridges Don't Sink

Anchor bolt fixing details | Footing, Pedestal reinforcements | 3d animation of Rc foundation

