Low AC Refrigerant Charge - How to be SURE (Does it really need Freon?)
Does the system really need Freon? In this video, Bryan shows how you can answer that question by covering the signs of low AC refrigerant charge. That way, you can be SURE about the answer. He describes the role of superheat and subcooling to verify that a system is low on charge so that you don’t add refrigerant unnecessarily. Subcooling tells us how much liquid is stacking in the condenser, with higher numbers representing more liquid and lower numbers indicating less liquid. We need to feed the metering device with a full column of liquid, but we don’t want excessive subcooling; too much liquid in the condenser will raise the head pressure and the compression ratio. In refrigeration, there will be a sight glass to indicate that you have a full line of liquid going to the metering device, so connecting gauges to check the subcooling is less important. Superheat indicates how much liquid we’re feeding the evaporator coil. High superheat indicates a starved evaporator, whereas low superheat may bring liquid back to the compressor. The superheat should be high enough to ensure that we won’t deal with compressor flooding, but it shouldn’t be high enough to indicate a starved evaporator coil. A visual inspection is also critical; filter restrictions, dirty coils, and improper thermostat settings may cause your readings to be off. Once you’ve verified that there are no obvious airflow issues, you can check the superheat and subcooling to begin verifying the charge level. Subcooling will generally be the main indicator of the charge level for modern residential systems. After subcooling, suction pressure warrants the most attention. You can figure out the suction pressure by figuring out the evaporator TD. You can then use that temperature to refer to a P-T chart to get the corresponding suction pressure. If the TD is lower than the design temperature difference (DTD), the system will have a lower suction pressure than normal. If the suction pressure is low, double-check to make sure that the coil isn’t frozen and that there are no airflow restrictions. We can also look at the condensing temperature over ambient (CTOA), which is usually more variable than the suction pressure. The CTOA refers to the difference between the saturation temperature at the condenser and the ambient temperature. In cases with a 15-degree design CTOA, the condensing temperature would be 15 degrees higher than the ambient temperature (105 degrees on a 90-degree day). We can then use the condensing temperature with a P-T chart or app to figure out the head pressure. A low delta T may also be an indicator of low charge. The telltale signs are a low condensing temperature, low evaporator temperature, low subcooling, and high superheat. To get the most accurate readings, you should ensure that there are NO airflow restrictions and that the Schrader cores have been depressed if you take your readings with gauges. Read all the tech tips, take the quizzes, and find our handy calculators at https://www.hvacrschool.com/.

Subcooling = Stacking Liquid Refrigerant (What Subcool really Signifies)

Refrigerant Overcharge Troubleshooting and Prevention

How to Check AC Freon Level

Checking the R-410A Refrigerant Charge! What to Watch Out For!

Setting a Refrigerant Charge by Subcool

Refrigeration Basics with Elliot and Bert Part 3

AC LOW on Refrigerant! How To Know!

How to Evacuate an AC system, Full Vacuum Procedure

Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!

Refrigerant Circuit Basics for HVAC techs

Saturation, Superheat, Subcooling

Residential Low Voltage HVAC Troubleshooting Class P1

The Refrigeration Cycle (SIMPLIFIED) - HVAC Training

How to Properly Vacuum and Recharge Car AC (R134a) - Step-by-Step DIY Guide

How To Add Refrigerant To Air Conditioner

What is Subcooling? - HVAC Training

Something is jamming GPS over Europe. Here's what we found

HVAC 108 Scenario Low on charge

Setting a Charge By Subcool on a TXV system In 3D

