PFIZER BUILDING: JACK IT UP! Repair Analysis
https://struct4u.com/downloads : Xconstruct if you want to play with Built-up sections Can the Pfizer Building structural failure be saved, or does the entire new construction need to be demolished? In this video, we analyze the structural integrity of the Pfizer Building expansion project (16 additional floors built on top of an existing roof structure) after the failure and buckling of critical support columns. We walk through the engineering behind the current temporary shoring system, model the structural forces and unwanted horizontal loads caused by the building sagging, and evaluate the two possible path forwards for repairs: Complete Demolition & Rebuild: Why removing the welded steel frames and concrete decks would mean throwing millions in work directly into the garbage. Hydraulic Jacking & Structural Stabilization: A step-by-step forensic engineering breakdown of how hydraulic jacks, tilting saddles, moment frames, and horizontal ties to neighboring structures could safely lift and restore the building into alignment. In this video, we cover: 00:00 — Introduction: Buckled columns & current shoring situation 00:40 — Reinforced vs. Unreinforced steel columns (3D structural software model) 01:40 — Failure modes: Wide flange (H-beam) buckling vs. square box profiles 02:11 — Why shoring must run continuously all the way to the foundation 02:50 — Differential settlement: Slanted frames and unexpected horizontal forces 04:00 — Option 1: Demolishing welded steel frames vs. Option 2: Hydraulic jacking 05:10 — Hydraulic jacking sequence: Moment frames, tilting saddles, & load distribution 06:18 — Managing horizontal force risks during the lifting procedure 07:20 — Load requirements (8,700 tons) & permanent reinforcement strategy What do you think is the most viable path forward for the developer? Let me know your thoughts in the comments! Subscribe to CIVILDETECTIVE for deep-dive structural analysis, forensic engineering case studies, and real-world failure investigations. #Engineering #ForensicEngineering #StructuralEngineering #PfizerBuilding #CIVILDETECTIVE #SteelStructures #BuildingFailure #Construction

This $400M NYC Skyscraper Can't Be Fixed and Can't Be Torn Down

Structural Engineer Speaks out about Column Failures in the Former Pfizer building New York City.

What Really Killed the American Home That Was Built to Last 100 Years

Pfizer Building Collapse EVIDENCE: Engineer Blames Builder

VIDEO of Tow Crash Aftermath, What Happened? | SY News Ep627

Nobody Explained the Schrödinger Equation Like THIS!

The World's Most Leaning Tower Isn't in Pisa — It's in Abu Dhabi

Miami's Newest Luxury Tower Is Already Falling Apart

Korean Air Flight 81 Suffers Hydraulic Failure Into JFK

Have We Finally Built Too Thin?

Texas' $200M Luxury Tower Began Cracking and Sinking — Then 55,000 Tons of Concrete Failed

Illegal Renovation That Condemned Empire Towers, Garage

NEW Pfizer Building Evidence: Engineer Or Builder Error?

They just started robbing everyone

OpenAI Claims Their AI 'Went Rogue'. It Didn't.

CHOSEN ONE!! YOUR IDENTITY REVEAL JUST SHOOK THE INTERNET... AND THEIR MINDS

CANADA FURIOUS: The 50% Tariff Nuke Just BLEW UP in Trump's Face

Ukraine Waited for Russia's Largest Ammunition Train to Enter the Tunnel — Then THIS Happened...

What's Under Your Feet in New York City?

