Sneaky Inverter Generator Fuel Shutoff Valve Trick Few People Know! [NOT IN THE MANUAL!]
Ever want to run your carburetor dry on your inverter generator but you can't find the shutoff valve? Here's a little trick that's NOT in the manual you can try that will only take a few minutes! Inverter generators often have a control panel with a knob that simply turns the generator on or off, and doesn't really offer an obvious method to turn off the fuel shutoff valve. When I put my generators away for storage, I typically run the carburetor dry and let the generator stall out instead of draining the carburetor after the engine turns off. It just saves a little time in the grand scheme of things. If you like to do this method as well but don't know how with an inverter generator go ahead and slowly turn the knob to the off position until the generator sounds like it's about to turn off. Quickly turn the knob back about 1/8 of an inch so that the generator stays running and doesn't stall out. This will, in effect, cut off the carburetor from the fuel supply. The generator will likely remain running for another 2-3 minutes before it will stall completely. Once that is done, turn off the fuel cap vent, and then turn the knob to the "off" position. Your generator's carburetor is now empty and is ready for storage until the next power outage!

Generator Runs Bad? Easy Carb Fix! WEN 2000W Inverter Generator Repair

7 Tips to Help Avoid Killing Your Generator.

Champion Generator ~ WON'T START ~ Dual Fuel

Generator Runs But No Power? Step-by-Step Troubleshooting & Repair Guide!

7 Backup Generator Mistakes. (Have You Made One?)

Generator Runs A Few Minutes & Dies - Here's Why!

GENERATOR SECRET Fuel shut off valve built in!!

The Good, the Bad, and what I've Learned so far with this WEN generator.

Mike Brewer Reveals The Truth About What Happened to Wheeler Dealers

Generator inverter Wen 3800w cannot start after sitting 2 years - thought auto-off burned all fuel

Generator Won’t Start The Most Overlooked Problem Not Fuel or Carb! Easy Fix & Diagnosis WGen9500DF

GENERATOR OVERCRANK | FAULT CODE 1100 TROUBLESHOOTING | FUEL & BATTERY CHECKS ⚡🔧

Sportsman Dual Fuel Inverter Generator Will NOT Start

Honda EU3000IS, Service a Non Running Generator

Generator won’t start DO THIS 5 Min fix!!

Propane Generator Fails You Keep Making!

Predator Super Quiet 9500 | Crank no start FIX

Homeowners are Destroying Generators Skipping 1 Step During a Power Outage

Generac Generator fix

