Metavision Training Videos | Trigger and Synchronization Interfaces

In this video, we are giving an overview on trigger and synchronization interfaces available in Prophesee EVKs/RDKs. These interfaces allow to send and receive trigger signals and also synchronize EVKs/RDKs with compatible hardware. Possible examples of use-cases are: synchronization of several EB cameras synchronization of EB + FB cameras synchronization of EB camera + illumination, like a signal from a light source, FB camera flash strobe, etc triggering EB camera by other equipment in automated processes We demonstrate two simple scenarios: external trigger signal as “Triger In” in EVK4 synchronizing two EVK4 cameras via “Sync In“ and “Sync Out“ Chapters: 00:00 Introduction 01:29 Documentation 02:57 Trigger In 03:22 Trigger In | How is "Trigger In" Interface Implemented in EVK? 06:08 Trigger In | How to Prepare a Trigger Cable for EVK4? 07:07 Trigger In | Generating a "Trigger In" Signal for EVK4 09:01 Trigger In| How to Capture and Access "External Trigger Events" in the Data Stream? 11:22 Synchronization 11:38 Synchronization | How Synchronization is "Sync" Interface Implemented in EVK? 12:20 Synchronization | Example of Setup Synchronizing two EVK4 14:06 Synchronization | How to Capture Synchronized Data with Metavision SDK? 15:26 Conclusion Useful links: Basics on timing interfaces - https://docs.prophesee.ai/stable/hw/m... Camera synchronization - https://docs.prophesee.ai/stable/hw/m... Overview on Trigger/Sync doc in KC and links to the camera manuals - https://support.prophesee.ai/portal/e... Getting Started with Trigger using Metavision SDK - https://support.prophesee.ai/portal/e... FAQ – https://docs.prophesee.ai/stable/faq.... Questions ? Email us at [email protected]