Inside a lamp post connection and cut-out unit.
This is a very good example of something that has been designed with function in mind. It's a robust connection point that allows easy termination of cables in a lamp post with an HRC fuse suited to the potential high fault current that can occur, and a large integrated finger guard on the fuse holder. John Ward has a video showing a dual fuse unit with phase and neutral isolation here:- • Bill Street Lighting Cutout SL3D2 The most important thing to know about these units is that you must ONLY use the correct type of fuse. Many posts are fed directly from a utility company supply cable and the potential fault current in the event of a short circuit from phase to neutral or ground is measured in thousands of amps. Never replace the fuse with a bit of wire, foil or an unsuitable fuse. My dislike for traditional wire armour glands is down to terminating a lot of them in the past. Often with several staggered rows entering a control panel. Even if the glands are all tightened in before the cables are inserted, the act of tightening the collar to grip the armour often creates a slight twist in the armour and upon release it can loosen the gland. Especially when dressing the cables into ladder or tray. The flat internal nuts are just so unsuited to the purpose. Pre-rounded edges and nothing to really bite or grip when tightened. I'm quite fond of street lighting stuff. Not so much when it's pouring with rain in winter, but cherrypickers/bucket trucks/van mounts are pretty much all big boys toys. And not too many "safety officers" due to the unglamorous nature of the work. If you enjoy these videos you can help support the channel with a dollar for coffee, cookies and random gadgets for disassembly at:- http://www.bigclive.com/coffee.htm This also keeps the channel independent of YouTube's advertising algorithms allowing it to be a bit more dangerous and naughty.

Inside a new Philips ultra-efficient LED lamp (with schematic)

Autopsy of Kawasaki relay box.

95% of people are doing this terminal block WRONG‼️

Inside a Japanese street light time switch.

Most Ridiculous Worker Mistakes Caught on Camera

Why Put A Capacitor Across The Diode? Here's Why!

Did The Regs Ban These Junction Boxes?

Unbelievable Smart Worker & Hilarious Fails | Construction Compilation #5 #adamrose #smartworkers

Stop buying new spray paint! Easy way to refill an old spray paint can!

Inside Dyson’s Overengineered £1000 Hand Dryer

Autopsy of faulty LED lamp. 670 volt PSU! with schematic.

The Best Cable - Wire For Audio? Let's Look Closer!

MOSFET vs Transistor vs Relay: Most People Get This Wrong

It's NOT SWA Cable Feeding Your House Cutout Fuse

Bill Street Lighting Cutout SL3D2

Fault Finding a Scary Lighting Circuit - Electrician Life

What is inside a streetlight?

Lamp post not working? Properly rewire making trenched area invisible when finished.

OSRAM LED lamp module autopsy.