TEKNİM KONVAKSİYONEL YANGIN ALARMI NASIL KURULUR DEDEKTÖRLERİN BAĞLANTILARI #teknim #alarmpaneli

TFS-3192R / TFB-3165 / TFD-4230 / TFD-4240 / TFD-4250 / TFD-3230 / TFD-3240 / TFD-3250 TEKNİM PRODUCTS ARE FULLY UNIVERSAL, SO YOU CAN USE OUR DETECTORS ON ANY PANEL YOU WANT. TEKNİM PANELS AND FEATURES TFP-3122 2-Zone Conventional Fire Alarm Panel: Supports up to 32 devices per zone Distinguishes whether alarm information is a button or a detector TXM-5271 (Ethernet) or TXM-5474 (LTE) modules for instant control and notifications via web browser or mobile app General delay time definition from 1 to 10 minutes "Fire and Fault/Disable/Test" LEDs for zones Metal box Used with 1 12V 7Ah battery TFP-3124 4-Zone Conventional Fire Alarm Panel Up to 32 detectors can be connected to each zone Distinguish between button and detector alarms Web browser control and instant notifications with TXM-5271 (Ethernet) or TXM-5474 (LTE) modules SMS sending with TXM-5474 LTE module General delay time definition from 1 to 10 minutes Easy programming with operation codes "Fire and Fault/Disable/Test" LEDs for zones Simple and intuitive system structure with error, warning, and alarm indicators Smart charging system that extends battery life Smart system shutdown protects battery life when voltage drops below 10.5 VDC. Siren output and zone input end-of-line resistors are monitored for incorrect connections. Zone test feature. 24 VDC 300mA external power output (AUX) with automatic fuse. 1 NC/NO alarm relay (Button alarm, detector alarm, etc.) 1 NC/NO fault relay (Power fault, zone fault, battery fault, etc.) Disabling of selected zones. Switched power supply. Metal case. Used with 1 12V 7Ah battery. TFP-4404 4-Zone Conventional Fire Alarm Panel (Metal Case). Fully monitored 4-zone capacity. Up to 32 TEKNİM conventional fire detectors can be connected to each zone. User-friendly, easy-to-manage display panel. Separate fire and fault LEDs for each zone. Smart charging system extends battery life. Smart protection system prevents the device from starting directly from battery power for safety reasons. One-person walk test function Ability to disable each zone individually Ability to monitor sounder outputs and zone inputs using end-of-line resistors to prevent incorrect connections A coded operation system that determines the intervention authorization level A removable cover design for easy installation Switched-mode (SMPS) power supply (24VDC SMPS with 1.5Ah automatic fuse) TFP-4408 8-Zone Conventional Fire Alarm Panel (Metal Case) Fully monitored 8-zone capacity Up to 32 TEKNİM conventional fire detectors can be connected to each zone User-friendly, easy-to-manage display panel Separate fire and fault LEDs for each zone Smart charging system that extends battery life Smart protection system that prevents the device from starting directly from the battery for safety reasons Ability to disable each zone individually Ability to monitor sounder outputs and zone inputs using end-of-line resistors to prevent incorrect connections With two 500mA sounder outputs, up to Up to 50 Teknim TFS-3192 sirens can be connected. 24 VDC 500mA external power output (AUX) with automatic fuse. 1 NC/NO alarm relay (Button alarm, detector alarm, etc.) 1 NC/NO fault relay (Power fault, zone fault, battery fault, etc.) Operation code system that determines intervention authorization level. Removable cover design for easy installation. Switched-mode (SMPS) power supply (24VDC SMPS 1.5Ah with automatic fuse).