{773} Split AC Indoor Unit Board Not Powering On
in this video number {773} i repaired how to repair Hisense Split AC Indoor Unit Board Not Powering On PCB05-350-V02, 1418659, W10324338, it is used in hisense, PLACA, Plaqueta Aire Acondicionado Whirlpool Wbc18c, 1.5 ton split ac indoor unit. this board was not power on, its switch mode power supply using Q100/ FSQ100 SMPS controller ic. i found diode 1N4007 short circuit in RCD snubber circuit. which was causing to drop 5 volt to 1 volt with fluctuations. You are Invited to Join Haseeb Electronics / @haseebelectronics #electronicscreators #tutorial #electronics how to repair split ac, how to repair split ac indoor unit, indoor unit board repair, indoor unit circuit repair, indoor unit, how repair indoor unit circuit, ac pcb repair, troubleshooting, indoor unit error, ac pcb service, ac pcb repairing course, how repair split ac, split ac power not start, why not start ac, split ac contactor start nahi hota hai, indoor unit pcb, haseeb electronics, how to repair smps, how to repair switch mode power supply, switch mode power supply, very easy repair of smps, smps output fluctuating, switching power supply repair, smps controller ic, smps output voltage fluctuation

{775} LCD TV Power Supply No Power ON, Not Turning ON

{972C} Repairing STR3A155 based power Supply in LG Inverter AC Board

15 18 VFD Repairing | Module Blast | attari Electronics |Ahmad Raza attari

20W LED Ceiling Light Repair | LED Strip Bypass + How to Decrease LED Driver Current || EP #1465

Fixing Mini Split AC Dead Motherboard, That Won't Power On!!

{950} Gree DC inverter AC indoor unit circuit explained

The Nightmare PCB Repair: When Replacing EVERYTHING Isn't Enough

Photographers Who Became Friends With Wildlife in the Sweetest Way! 😍🐾

Mini Split AC Circuit Repair, Not Able To Start Compressor

Integrated SSDs Should Be Illegal, But Why Would They Care!

LG Inverter Mini Split PCB Was Completely Dead… Can I Fix It?

✅ Secrets to Repairing an Embraco VCC3 EG Inverter Board❗️

Hp 255 G9 no power, not charging - The most underrated component which can give you nightmare faults

{770} SMPS Is Not Working || SMPS Not Turning ON

{933} Power adapter not turning on

{1066} Delta 24V SMPS no output voltage, short circuit on DC line

Haier AC Indoor Circuit Board REPAIR - Tips For Low Volt Section

LG Mini Split AC CH05 Error Fix! Surprising Circuit Board Repair

How To Find The Faulty Component On A PCB Without Schematics : A Very Practical Repair Example!

