🟠 COMO Configurar central FACILITY Connect PPA + PROG funções PART3

"G|A|R|C|I|A_T|E|C" , "G|A|R|C|I|A_T|E|C", PPA Board Facility Board P02239 P22 Remote control gate opener program electronic gate how to install an electronic gate motor | GARCIATEC Channel Thanks for visiting 💪🛠⚙ ✍🏻 Subscribe to the channel:    / garciatec   🏪 Product store: https://bit.ly/3pzEmDO 🎬 Video:    • 🟠 COMO Configurar central FACILITY Connect...   MANUAL: -RECORDING TRANSMITTERS The control panel allows you to record up to 160 different transmitters, independent of the buttons. To record transmitters: 1. The gate must be stopped and not be timing for automatic closing. 2. Close the PROG jumper. The green SN LED should remain dimly lit. 3. Press and hold the transmitter button. The green SN LED should flash. 4. Press and release the RECORD button and check the SN LED: If the SN LED flashes once: The transmitter button has been recorded. If the SN LED flashes twice: The transmitter button has already been recorded. If the SN LED flashes three times: The memory is full. 5. Release the transmitter button. 6. To record other transmitter buttons, continue from step 3. 7. To complete the operation, open the PROG jumper. -SELECTING THE TRANSMITTER TYPE: FIXED OR ROLLING CODE 1. The gate must be stopped and not timing for automatic closing. 2. Close the PROG jumper. The green SN LED should remain dimly lit. 3. Simultaneously press and release both buttons on the transmitter (engraved) 10 times. The SN LED will flash each time the buttons are released. Wait 5 seconds. 4. Then, the SN LED will remain lit, waiting for the transmitter type to be configured. -SELECTING THE DIGITAL OR ANALOG LIMIT SWITCH SYSTEM 1. The gate must be stopped and not timing for automatic closing. 2. Keep the PROG jumper open. 3. Select the limit switch option using the FC jumper: FC Open: Analog Limit Switch. FC Closed: Digital Limit Switch. 4. After selecting the limit switch system, automatic path memorization will be necessary. Otherwise, if Digital Limit Switch is selected, the control unit will operate with a minimum path of 100 pulses. If Analog Limit Switch is selected, the opening/closing time will be 120 seconds. -ERASING ALL TRANSMITTERS FROM MEMORY 1. The gate must be stopped and not timing for automatic closing. 2. Close the PROG jumper. The green SN LED should remain dimly lit. 3. Simultaneously press and release both buttons on the transmitter (recorded) three times. The SN LED will flash each time the buttons are released. Wait 5 seconds. 4. Then, the SN LED will remain on, awaiting confirmation to delete the transmitters or cancel the operation. To cancel the operation: Press and release the transmitter's left button. The SN LED will return to a dim light. To delete all transmitters: Press and release the transmitter's right button. The SN LED will flash 3 times, indicating that all transmitters have been deleted. 5. Open the PROG jumper. -To restore factory default settings: 1. The gate must be stopped and not timing for automatic closing. 2. On the FC jumper, select the limit switch: Analog (FC open) or Digital (FC closed). 3. Close the PROG jumper. The green SN LED should remain dimly lit. 4. Press and release both transmitter buttons (recorded) simultaneously 4 times. The SN LED will flash each time the buttons are released. Wait 5 seconds. 5. The SN LED will flash 4 times, confirming the control unit reset. 6. Open the PROG jumper. Gate motor Electronic gate motor Overhead gate motor Do it yourself #ppa #facilityplate #ppamotor

How to configure the PPA Hybrid Agility Control Center, recording controls, route, fixed and roll...
▶︎

How to configure the PPA Hybrid Agility Control Center, recording controls, route, fixed and roll...

Programando a Central Agility Híbrida PPA com o programador PROG e uma novidade PPA na Exposeg
▶︎

Programando a Central Agility Híbrida PPA com o programador PROG e uma novidade PPA na Exposeg

Micom P546 Relay overview and Connect with softwere. #safety #micomP546 #protection  #testingguide
▶︎

Micom P546 Relay overview and Connect with softwere. #safety #micomP546 #protection #testingguide

Todas as funções da CENTRAL TRIFLEX FULL RANGE PPA sem o PROG
▶︎

Todas as funções da CENTRAL TRIFLEX FULL RANGE PPA sem o PROG

PPA P22451 - RESET PADRÃO DE FÁBRICA
▶︎

PPA P22451 - RESET PADRÃO DE FÁBRICA

Como Configurar Triflex Facility com o PROG da PPA - TODAS AS FUNÇÕES
▶︎

Como Configurar Triflex Facility com o PROG da PPA - TODAS AS FUNÇÕES

TUDO sobre a Central TRIFLEX FACILITY PPA com o PROG ( Final )
▶︎

TUDO sobre a Central TRIFLEX FACILITY PPA com o PROG ( Final )

Working on the Red Tractor: Engine Disassembly and Repair
▶︎

Working on the Red Tractor: Engine Disassembly and Repair

SEE HOW TO SOLVE A GATE WITHOUT POWER WHEN OPENING OR CLOSING FACILITY CONNECT PLATE
▶︎

SEE HOW TO SOLVE A GATE WITHOUT POWER WHEN OPENING OR CLOSING FACILITY CONNECT PLATE

New from PPA: Central de Portão Facility Connect
▶︎

New from PPA: Central de Portão Facility Connect

How to complete the configuration of the PPA electronic gate POP board
▶︎

How to complete the configuration of the PPA electronic gate POP board

🔴 Makkah Live | مكة مباشر | الحرم المكي مباشر | قناة القران الكريم السعودية مباشر | مكه المكرمه
▶︎

🔴 Makkah Live | مكة مباشر | الحرم المكي مباشر | قناة القران الكريم السعودية مباشر | مكه المكرمه

Beautiful Relaxing Music - Stop Overthinking, Stress Relief Music, Sleep Music, Calming Music #177
▶︎

Beautiful Relaxing Music - Stop Overthinking, Stress Relief Music, Sleep Music, Calming Music #177

PPA P22451 - MODO AUTOMÁTICO OU SEMIAUTOMÁTICO
▶︎

PPA P22451 - MODO AUTOMÁTICO OU SEMIAUTOMÁTICO

Electromagnetic gate lock, compatible with any PPA control unit. #centralfacility
▶︎

Electromagnetic gate lock, compatible with any PPA control unit. #centralfacility

como programar o percurso central ppa facility top
▶︎

como programar o percurso central ppa facility top

Central Pop Prog , PROGRAMAÇÃO DA RAMPA SEM O PROG.  #PPA, #BVSP, #MOTORPPA
▶︎

Central Pop Prog , PROGRAMAÇÃO DA RAMPA SEM O PROG. #PPA, #BVSP, #MOTORPPA

RELAY MODULE - EAD PPA Caxias
▶︎

RELAY MODULE - EAD PPA Caxias

🟠 COMO Configurar FACILITY TOP Hibrida PART5
▶︎

🟠 COMO Configurar FACILITY TOP Hibrida PART5

Central Agility POP PPA, Instalação e ativando suas funções SEM O PROG.
▶︎

Central Agility POP PPA, Instalação e ativando suas funções SEM O PROG.