How to Clean and Care for Your Midmark M9®/M11® Steam Sterilizer (Daily/Weekly Maintenance)
Video training guide—how to perform daily/weekly cleaning and maintenance on a Midmark steam sterilizer. Learn more at http://midmark.com. Video Transcript: This video is an overview of the daily and weekly maintenance of your autoclave. However always refer to the appropriate technical documentation for the complete list of instructions, safety alerts and sequence of procedures before conducting any service or maintenance operations. Your Midmark autoclave will provide many years of trouble-free service if recommendations for periodic maintenance are carefully followed. Recommended maintenance is easy to do and it takes very little time. If the recommended maintenance is not performed mineral deposits and corrosion can build up on the internal components resulting in operational problems, downtime and service fees. One of the most important steps you can take to prevent problems with your autoclave is to ensure that only distilled water, not tap water, is used in your autoclave. Since the autoclave operates with high water temperatures any minerals dissolved in the water will leave mineral deposits. This can prevent valves from opening or closing properly. It can also lead to corrosion in the chamber and tubing. To ensure proper operation and maximum sterilization life, the M9 and M11 provide the operator with maintenance reminders on the display screen. The reminders are removed from the display once a cycle is starting. The exterior of the autoclave should be wiped down each day. Use only quaternary disinfectants to disinfect the unit. Do not use alcohol or bleach based cleaners. The door gasket and door dam gasket should be inspected for damage. When the inspection is complete wipe with a damp cloth. If the autoclave processes instruments that have been lubricated or dipped in dental milk, the autoclave must be drained and refilled with distilled water every day. This prevents other items from being contaminated with the residue from these fluids. It also prevents excessive residue build-up from damaging the unit seals. Every seven days the autoclave will automatically display the "perform weekly maintenance" message. Weekly maintenance consists of two operations: changing the water in the unit and cleaning. After disconnecting the upper portion of the water level indicator bend it downward and let the reservoir drain in a suitable container, a bucket, for example. Remove the trays and rack from the autoclave. To remove the tray rack use a screwdriver and pry the tray up, while pulling the tray rack and plate out of the chamber. After removing the trays and rack from the autoclave, clean the trays and the inside of the chamber with distilled water and speed clean or mild soap. Bleaching agents and abrasives can damage metal surfaces and should never be used to clean the autoclave chamber. This includes steel wool, scouring powder, bleach or wire brushes. To install the tray rack and plate back in the unit, insert the tray rack into the tray plate. Press down on the tray rack while sliding it into the chamber. Refill the reservoir with distilled water until the water level indicator is in the green area. The "perform weekly maintenance" message will go away during your next sterilization cycle. For more detailed information about maintaining your autoclave, please refer to the M9/M11 installation and operation manual. For further support, contact Midmark Support Services at 1-800-MIDMARK.

How to Perform Monthly Maintenance on a Midmark M9®/M11® Steam Sterilizer

Daily, Weekly, and Monthly PM on the Midmark Ritter UltraClave Sterilizer

CLEANING AN M11 ULTRACLAVE AUTOMATIC STERILIZER

Midmark® M9 + M11 Steam Sterilizers: Monthly Maintenance

Instrument Reprocessing – From Dirty to Clean

Crosstex/SPS - Cleaning, Packaging & Sterilization

The FULL VIDEO of Trump they didn’t want released

How to Clean and Maintain Your Tuttnauer Automatic Autoclave - Part 2

Daily + Weekly Maintenance - Midmark® M9 + M11 Steam Sterilizers

Autoclave Sterilizing

Automatic packaging machines and packaging systems for Kits

Autoclaves Maintenance

Ritter M9/M11 Steam Sterilizer - Monthly Maintenance

Beautiful Relaxing Music - Stop Overthinking, Stress Relief Music, Sleep Music, Calming Music #242

Midmark M9/M11 New Style Monthly Maintenance

Unbelievable Workers | Working with Talented Engineers #46 #fail #adamrose #smartworkers

Autoclave Operation

How to Operate a Midmark M9®/M11® Steam Sterilizer

Guided Biofilm Therapy & EMS Airflow Prophylaxis Master Assembly, Use, Disassembly, and Disinfection

