Hot Gas Reheat Function and Purpose
Indoor air quality (IAQ) and occupant comfort are two of the most important factors for any HVAC system design. HVAC-TV YouTube channel: / @hvac-tv The Engineers HVAC Podcast: https://podcasters.spotify.com/pod/sh... Insight Partners Commercial HVAC: https://www.insightusa.com Hobbs & Associates Commercial HVAC: https://www.hobbsassociates.com Tony Mormino on LinkedIn: / tony-mormino One of the leading causes of poor IAQ and occupant discomfort is too much moisture in the air, commonly referred to as high humidity. IAQ problems associated with high humidity include mold growth, condensation, increased sickness, and allergic reactions. As for occupant comfort, the saying goes, “It’s not the heat; it’s the humidity.” Improving indoor air quality and occupant comfort by controlling the humidity and the temperature will help with these problems, boost productivity, and even improve the general well-being of the occupants. Controlling temperature and humidity over all load conditions takes some planning when designing your HVAC system. To do this properly, we must understand the purpose and function of Modulating Hot Gas Reheat. Modulating Hot Gas Reheat consists of a reheat coil downstream of the evaporator coil, a modulating reheat hot gas valve, a modulating condenser hot gas valve, and a reheat controller. The evaporator coil cools the mixed air below the dew point and then reheats the air with the reheat coil. The modulating valves allow only the needed amount of reheat, creating a consistent supply of air temperature. Modulating hot gas reheat is the solution to controlling high humidity loads.

DX Applications In Surgery Suites

Showing TXV Operation with a Water Stream! Thermostatic Expansion Valve Explained!

Making New Nuclear Fuel for an Atomic Renaissance | Bloomberg Primer

Psychrometrics Part 1 - How To Read the Psychrometric Chart

Hot Gas Reheat Vs. Hot Gas Bypass - What You Need To Know

Dehumidification and Reheat Talk

VAV Variable Air Volume - HVAC system basics hvacr

Addison Liquid Subcooling & Hot Gas Reheat

Humidity Basics

Psychrometrics Part 3 - Solving for Humidity

Why DX Systems Fail To Control Humidity!

Know Hot Gas Bypass? Advanced Refrigeration 2022 Part 1

Commercial HVAC Controls 101 - From Basic To Advanced

Hot Gas Bypass Valve Application and Low Load Conditions

Psychrometrics Part 2: SHR, Calculating CFM & Tons of Refrigeration

Psychrometrics Made Simple

Dehumidifiers are confusing. Here's why.

How To Read A Psychrometric Chart | 15 Minute HVAC Tutorial

🚗 BYD : The biggest SCAM of the car industry ?

